revised and updated
This commit is contained in:
parent
09377f3ab8
commit
6f8f604b2d
4
CLIENT_DATA/service_batch.bat
Normal file
4
CLIENT_DATA/service_batch.bat
Normal file
@ -0,0 +1,4 @@
|
||||
rundll32 user32.dll LockWorkStation %windir%
|
||||
ms-activation.vbs
|
||||
sc config opsiclientd start= auto
|
||||
net start opsiclientd
|
@ -1,101 +1,193 @@
|
||||
; Copyright (c) uib gmbh (www.uib.de)
|
||||
; This sourcecode is owned by uib
|
||||
; and published under the Terms of the General Public License.
|
||||
; credits: http://www.opsi.org/credits/
|
||||
|
||||
[Actions]
|
||||
requiredWinstVersion >= "4.10.8.6"
|
||||
|
||||
DefVar $MsiId$
|
||||
DefVar $UninstallProgram$
|
||||
DefVar $LogDir$
|
||||
DefVar $ProductId$
|
||||
DefVar $MinimumSpace$
|
||||
DefVar $InstallDir$
|
||||
DefVar $ExitCode$
|
||||
DefVar $LicenseRequired$
|
||||
DefVar $LicenseKey$
|
||||
DefVar $LicensePool$
|
||||
|
||||
Set $LogDir$ = "%SystemDrive%\tmp"
|
||||
|
||||
; The token BUILDER_VARIABLES will be replaced by opsi-builder.sh
|
||||
; and adds the following variables:
|
||||
; from builder-product.cfg : all variables definded by attribute WINST[index]
|
||||
; from builder-product.cfg : VENDOR PN VERSION RELEASE PRIORITY ADVICE TYPE
|
||||
; from opsi-builder.cfg : CREATOR_TAG CREATOR_NAME CREATOR_EMAIL
|
||||
; auto generated winst-variables
|
||||
; $IconFile$: path to product picture
|
||||
;
|
||||
@@BUILDER_VARIABLES@@
|
||||
|
||||
; ----------------------------------------------------------------
|
||||
; - Please edit the following values -
|
||||
; ----------------------------------------------------------------
|
||||
;$ProductId$ should be the name of the product in opsi
|
||||
; therefore please: only lower letters, no umlauts,
|
||||
; no white space use '-' as a seperator
|
||||
Set $ProductId$ = "windows.activation"
|
||||
Set $MinimumSpace$ = "1 MB"
|
||||
; the path were we find the product after the installation
|
||||
Set $InstallDir$ = "%ProgramFiles32Dir%\<path to the product>"
|
||||
Set $LicenseRequired$ = "false"
|
||||
Set $LicensePool$ = "p_" + $ProductId$
|
||||
; ----------------------------------------------------------------
|
||||
|
||||
if not(HasMinimumSpace ("%SystemDrive%", $MinimumSpace$))
|
||||
LogError "Not enough space on %SystemDrive%, " + $MinimumSpace$ + " on drive %SystemDrive% needed for " + $ProductId$
|
||||
isFatalError
|
||||
; Stop process and set installation status to failed
|
||||
else
|
||||
; comment "Show product picture"
|
||||
; ShowBitmap "%ScriptPath%\" + $ProductId$ + ".png" $ProductId$
|
||||
|
||||
if FileExists("%ScriptPath%\delsub32.ins")
|
||||
comment "Start uninstall sub section"
|
||||
Sub "%ScriptPath%\delsub32.ins"
|
||||
endif
|
||||
|
||||
Message "Installing " + $ProductId$ + " ..."
|
||||
|
||||
if $LicenseRequired$ = "true"
|
||||
comment "Licensing required, reserve license and get license key"
|
||||
Sub_get_licensekey
|
||||
endif
|
||||
|
||||
|
||||
comment "Copy files"
|
||||
Files_install
|
||||
|
||||
comment "Start setup program"
|
||||
Winbatch_install
|
||||
Sub_check_exitcode
|
||||
|
||||
comment "Reboot"
|
||||
ExitWindows /Reboot
|
||||
|
||||
endif
|
||||
|
||||
[Files_install]
|
||||
copy "%ScriptPath%\ms-activation.vbs" %System%
|
||||
|
||||
[Winbatch_install]
|
||||
; Choose one of the following examples as basis for your installation
|
||||
; You can use $LicenseKey$ var to pass a license key to the installer
|
||||
;
|
||||
; === Nullsoft Scriptable Install System ================================================================
|
||||
|
||||
ms-activation.vbs
|
||||
|
||||
[Sub_check_exitcode]
|
||||
comment "Test for installation success via exit code"
|
||||
set $ExitCode$ = getLastExitCode
|
||||
; informations to exit codes see
|
||||
; http://msdn.microsoft.com/en-us/library/aa372835(VS.85).aspx
|
||||
; http://msdn.microsoft.com/en-us/library/aa368542.aspx
|
||||
if ($ExitCode$ = "0")
|
||||
comment "Looks good: setup program gives exitcode zero"
|
||||
else
|
||||
comment "Setup program gives a exitcode unequal zero: " + $ExitCode$
|
||||
isFatalError
|
||||
endif
|
||||
; Copyright (c) uib gmbh (www.uib.de)
|
||||
; This sourcecode is owned by uib
|
||||
; and published under the Terms of the General Public License.
|
||||
; credits: http://www.opsi.org/credits/
|
||||
|
||||
[Actions]
|
||||
requiredWinstVersion >= "4.10.8.6"
|
||||
|
||||
|
||||
DefVar $Proxy_Port$
|
||||
DefVar $Flag$
|
||||
DefVar $WinstRegKey$
|
||||
DefVar $MsiId$
|
||||
DefVar $UninstallProgram$
|
||||
DefVar $LogDir$
|
||||
DefVar $ProductId$
|
||||
DefVar $MinimumSpace$
|
||||
DefVar $InstallDir$
|
||||
DefVar $ExitCode$
|
||||
DefVar $LicenseRequired$
|
||||
DefVar $LicenseKey$
|
||||
DefVar $LicensePool$
|
||||
|
||||
Set $LogDir$ = "%SystemDrive%\tmp"
|
||||
Set $WinstRegKey$ = "HKLM\SOFTWARE\opsi.org\winst"
|
||||
Set $Flag$ = GetRegistryStringValue32("["+$WinstRegKey$+"] "+"RebootFlag")
|
||||
Set $Proxy_Port$ = "pubproxy:3128"
|
||||
|
||||
; The token BUILDER_VARIABLES will be replaced by opsi-builder.sh
|
||||
; and adds the following variables:
|
||||
; from builder-product.cfg : all variables definded by attribute WINST[index]
|
||||
; from builder-product.cfg : VENDOR PN VERSION RELEASE PRIORITY ADVICE TYPE
|
||||
; from opsi-builder.cfg : CREATOR_TAG CREATOR_NAME CREATOR_EMAIL
|
||||
; auto generated winst-variables
|
||||
; $IconFile$: path to product picture
|
||||
;
|
||||
DefVar $VENDOR$
|
||||
Set $VENDOR$ = "microsoft.com"
|
||||
DefVar $PN$
|
||||
Set $PN$ = "windows.activation"
|
||||
DefVar $VERSION$
|
||||
Set $VERSION$ = "1"
|
||||
DefVar $RELEASE$
|
||||
Set $RELEASE$ = "5"
|
||||
DefVar $PRIORITY$
|
||||
Set $PRIORITY$ = "0"
|
||||
DefVar $ADVICE$
|
||||
Set $ADVICE$ = ""
|
||||
DefVar $TYPE$
|
||||
Set $TYPE$ = "public"
|
||||
DefVar $CREATOR_TAG$
|
||||
Set $CREATOR_TAG$ = "dt"
|
||||
DefVar $CREATOR_NAME$
|
||||
Set $CREATOR_NAME$ = "Dennis Trinks"
|
||||
DefVar $CREATOR_EMAIL$
|
||||
Set $CREATOR_EMAIL$ = "dennis.trinks@dtnet.de"
|
||||
DefVar $IconFile$
|
||||
Set $IconFile$ = "%ScriptPath%\windows.activation.png"
|
||||
|
||||
|
||||
; ----------------------------------------------------------------
|
||||
; - Please edit the following values -
|
||||
; ----------------------------------------------------------------
|
||||
;$ProductId$ should be the name of the product in opsi
|
||||
; therefore please: only lower letters, no umlauts,
|
||||
; no white space use '-' as a seperator
|
||||
Set $ProductId$ = "windows.activation"
|
||||
Set $MinimumSpace$ = "1 MB"
|
||||
; the path were we find the product after the installation
|
||||
Set $InstallDir$ = "%ProgramFiles32Dir%\<path to the product>"
|
||||
Set $LicenseRequired$ = "false"
|
||||
Set $LicensePool$ = "p_" + $ProductId$
|
||||
; ----------------------------------------------------------------
|
||||
|
||||
if not(HasMinimumSpace ("%SystemDrive%", $MinimumSpace$))
|
||||
LogError "Not enough space on %SystemDrive%, " + $MinimumSpace$ + " on drive %SystemDrive% needed for " + $ProductId$
|
||||
isFatalError
|
||||
; Stop process and set installation status to failed
|
||||
else
|
||||
; comment "Show product picture"
|
||||
; ShowBitmap "%ScriptPath%\" + $ProductId$ + ".png" $ProductId$
|
||||
|
||||
if FileExists("%ScriptPath%\delsub32.ins")
|
||||
comment "Start uninstall sub section"
|
||||
Sub "%ScriptPath%\delsub32.ins"
|
||||
endif
|
||||
|
||||
Message "Installing " + $ProductId$ + " ..."
|
||||
|
||||
if $LicenseRequired$ = "true"
|
||||
comment "Licensing required, reserve license and get license key"
|
||||
Sub_get_licensekey
|
||||
endif
|
||||
|
||||
if $Flag$ = ""
|
||||
Set $Flag$ = "1"
|
||||
Registry_SaveRebootFlag
|
||||
DOSInAnIcon_AddActivationAdmin
|
||||
DOSInAnIcon_deactOpsiSrv
|
||||
; DOSInAnIcon_SetProxy
|
||||
Files_install_servicebatch
|
||||
Files_install
|
||||
Registry_SetAutoadmin
|
||||
Registry_SetRunOnce
|
||||
ExitWindows /ImmediateReboot
|
||||
Endif
|
||||
|
||||
if $Flag$ = "1"
|
||||
Set $Flag$ = "2"
|
||||
DOSInAnIcon_deactOpsiSrv
|
||||
Registry_SetRunOnce
|
||||
Registry_SaveRebootFlag
|
||||
ExitWindows /ImmediateReboot
|
||||
Endif
|
||||
|
||||
if $Flag$ = "2"
|
||||
Set $Flag$ = "3"
|
||||
Registry_SaveRebootFlag
|
||||
Registry_DisableAutoadmin
|
||||
ExitWindows /ImmediateReboot
|
||||
Endif
|
||||
|
||||
|
||||
if $Flag$ = "3"
|
||||
Registry_DeleteRebootFlag
|
||||
DOSInAnIcon_DeleteActivationAdmin
|
||||
Endif
|
||||
endif
|
||||
|
||||
[Files_install_servicebatch]
|
||||
copy "%ScriptPath%\service_batch.bat" "C:\tmp"
|
||||
|
||||
[Files_install]
|
||||
copy "%ScriptPath%\ms-activation.vbs" %System%
|
||||
|
||||
[Winbatch_install]
|
||||
; Choose one of the following examples as basis for your installation
|
||||
; You can use $LicenseKey$ var to pass a license key to the installer
|
||||
;
|
||||
; === Nullsoft Scriptable Install System ================================================================
|
||||
|
||||
ms-activation.vbs
|
||||
|
||||
[Sub_check_exitcode]
|
||||
comment "Test for installation success via exit code"
|
||||
set $ExitCode$ = getLastExitCode
|
||||
; informations to exit codes see
|
||||
; http://msdn.microsoft.com/en-us/library/aa372835(VS.85).aspx
|
||||
; http://msdn.microsoft.com/en-us/library/aa368542.aspx
|
||||
if ($ExitCode$ = "0")
|
||||
comment "Looks good: setup program gives exitcode zero"
|
||||
else
|
||||
comment "Setup program gives a exitcode unequal zero: " + $ExitCode$
|
||||
isFatalError
|
||||
endif
|
||||
|
||||
[Registry_SaveRebootFlag]
|
||||
openKey [$WinstRegKey$]
|
||||
set "RebootFlag" = "$Flag$"
|
||||
|
||||
[Registry_DeleteRebootFlag]
|
||||
openKey [$WinstRegKey$]
|
||||
DeleteVar "RebootFlag"
|
||||
|
||||
[Registry_SetAutoadmin]
|
||||
openkey [HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon]
|
||||
set "DefaultUserName"="activationadmin"
|
||||
set "DefaultPassword"="4ct1vat!0n"
|
||||
set "DefaultDomainName"="%PCName%"
|
||||
set "AutoAdminLogon"="1"
|
||||
|
||||
[Registry_DisableAutoadmin]
|
||||
openkey [HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon]
|
||||
set "DefaultUserName"=""
|
||||
set "DefaultPassword"=""
|
||||
set "AutoAdminLogon"="0"
|
||||
|
||||
[Registry_SetRunOnce]
|
||||
openkey [HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\RunOnce]
|
||||
set "OpsiService"="C:\tmp\service_batch.bat"
|
||||
|
||||
[DOSInAnIcon_AddActivationAdmin]
|
||||
net user activationadmin 4ct1vat!0n /add
|
||||
net localgroup Administratoren /add activationadmin
|
||||
|
||||
[DOSInAnIcon_DeleteActivationAdmin]
|
||||
net user activationadmin /delete
|
||||
|
||||
[DOSInAnIcon_SetProxy]
|
||||
proxycfg -p $Proxy_Port$
|
||||
|
||||
[DOSInAnIcon_deactOpsiSrv]
|
||||
sc config opsiclientd start= disabled
|
||||
|
Loading…
Reference in New Issue
Block a user