change LogDir; add ProductProperty desktoplink, custom-post-install, custom-post-uninstall
This commit is contained in:
parent
4f03ee401e
commit
a6bf8fdbcc
@ -67,6 +67,17 @@ endif
|
||||
comment "Delete program shortcuts"
|
||||
LinkFolder_uninstall
|
||||
|
||||
DefVar $Property_CustomPostUninstall$
|
||||
Set $Property_CustomPostUninstall$ = getProductProperty("custom-post-uninstall","none")
|
||||
if not ($Property_CustomPostUninstall$ = "none")
|
||||
comment "Include custom post uninstall file"
|
||||
if FileExists("%ScriptPath%\custom\" + $Property_CustomPostUninstall$)
|
||||
sub_CustomPostUninstall
|
||||
else
|
||||
LogError "Include script NOT exists (" + $Property_CustomPostUninstall$ +")"
|
||||
endif
|
||||
endif
|
||||
|
||||
[Winbatch_uninstall_msi_old_32]
|
||||
msiexec /x $MsiIdOld32$ /qb! REBOOT=ReallySuppress
|
||||
|
||||
@ -102,9 +113,12 @@ del -sf "$InstallDir64$\"
|
||||
;
|
||||
; Example of deleting a shortcut from AllUsers desktop:
|
||||
;
|
||||
; set_basefolder common_desktopdirectory
|
||||
; set_subfolder ""
|
||||
; delete_element $ProductId$
|
||||
set_basefolder common_desktopdirectory
|
||||
set_subfolder ""
|
||||
delete_element $NAME$
|
||||
|
||||
[sub_CustomPostUninstall]
|
||||
include_insert "%ScriptPath%\custom\" + $Property_CustomPostUninstall$
|
||||
|
||||
[Sub_check_exitcode]
|
||||
comment "Test for installation success via exit code"
|
||||
|
@ -23,10 +23,14 @@ DefVar $OLD_VERSION$
|
||||
DefVar $OLD_CREATOR_TAG$
|
||||
DefVar $OLD_RELEASE$
|
||||
|
||||
;Property Variables
|
||||
DefVar $Property_CustomPostInstall$
|
||||
DefVar $Property_DesktopLink$
|
||||
|
||||
Set $INST_SystemType$ = GetSystemType
|
||||
set $INST_architecture$ = GetProductProperty("install_architecture","system specific")
|
||||
|
||||
Set $LogDir$ = "%SystemDrive%\tmp"
|
||||
Set $LogDir$ = "%opsiLogDir%"
|
||||
|
||||
; The token BUILDER_VARIABLES will be replaced by opsi-builder.sh
|
||||
; and adds the following variables:
|
||||
@ -79,6 +83,10 @@ else
|
||||
Registry_install /32Bit
|
||||
comment "Create shortcuts"
|
||||
LinkFolder_install
|
||||
Set $Property_DesktopLink$ = GetProductProperty("DesktopLink","false")
|
||||
if ($Property_DesktopLink$ = "true")
|
||||
LinkFolder_install_DesktopLink_32
|
||||
endif
|
||||
endif
|
||||
|
||||
if ($INST_SystemType$ = "64 Bit System") and (($INST_architecture$ = "system specific") or ($INST_architecture$ = "both") or ($INST_architecture$ = "64 only"))
|
||||
@ -93,6 +101,20 @@ else
|
||||
Registry_install /64Bit
|
||||
comment "Create shortcuts"
|
||||
LinkFolder_install
|
||||
Set $Property_DesktopLink$ = GetProductProperty("DesktopLink","false")
|
||||
if ($Property_DesktopLink$ = "true")
|
||||
LinkFolder_install_DesktopLink_64
|
||||
endif
|
||||
endif
|
||||
|
||||
Set $Property_CustomPostInstall$ = getProductProperty("custom-post-install","none")
|
||||
if not ($Property_CustomPostInstall$ = "none")
|
||||
comment "Include custom post install file"
|
||||
if FileExists("%ScriptPath%\custom\" + $Property_CustomPostInstall$)
|
||||
sub_CustomPostInstall
|
||||
else
|
||||
LogError "Include script NOT exists (" + $Property_CustomPostInstall$ +")"
|
||||
endif
|
||||
endif
|
||||
|
||||
endif
|
||||
@ -161,6 +183,41 @@ copy "$IniCfgFile$" "$InstallDir64$"
|
||||
; icon_index: 2
|
||||
; end_link
|
||||
|
||||
[LinkFolder_install_DesktopLink_32]
|
||||
;
|
||||
; Example of creating an shortcut to the installed exe on AllUsers desktop:
|
||||
;
|
||||
set_basefolder common_desktopdirectory
|
||||
set_subfolder ""
|
||||
;
|
||||
set_link
|
||||
name: $NAME$
|
||||
target: "$InstallDir32$\putty.exe"
|
||||
parameters:
|
||||
working_dir: $InstallDir32$
|
||||
icon_file:
|
||||
icon_index:
|
||||
end_link
|
||||
|
||||
[LinkFolder_install_DesktopLink_64]
|
||||
;
|
||||
; Example of creating an shortcut to the installed exe on AllUsers desktop:
|
||||
;
|
||||
set_basefolder common_desktopdirectory
|
||||
set_subfolder ""
|
||||
;
|
||||
set_link
|
||||
name: $NAME$
|
||||
target: "$InstallDir64$\putty.exe"
|
||||
parameters:
|
||||
working_dir: $InstallDir64$
|
||||
icon_file:
|
||||
icon_index:
|
||||
end_link
|
||||
|
||||
[sub_CustomPostInstall]
|
||||
include_insert "%ScriptPath%\custom\" + $Property_CustomPostInstall$
|
||||
|
||||
[Sub_check_exitcode]
|
||||
comment "Test for installation success via exit code"
|
||||
set $ExitCode$ = getLastExitCode
|
||||
|
@ -25,7 +25,7 @@ DefVar $OLD_RELEASE$
|
||||
Set $INST_SystemType$ = GetSystemType
|
||||
set $INST_architecture$ = GetProductProperty("install_architecture","system specific")
|
||||
|
||||
Set $LogDir$ = "%SystemDrive%\tmp"
|
||||
Set $LogDir$ = "%opsiLogDir%"
|
||||
|
||||
; The token BUILDER_VARIABLES will be replaced by opsi-builder.sh
|
||||
; and adds the following variables:
|
||||
|
24
OPSI/control
24
OPSI/control
@ -30,6 +30,30 @@ description: which architecture (32/64 bit) has to be installed
|
||||
values: ["32 only", "64 only", "both", "system specific"]
|
||||
default: ["system specific"]
|
||||
|
||||
[ProductProperty]
|
||||
type: bool
|
||||
name: desktoplink
|
||||
description: Show Desktop Link on/off
|
||||
default: False
|
||||
|
||||
[ProductProperty]
|
||||
type: unicode
|
||||
name: custom-post-install
|
||||
multivalue: False
|
||||
editable: True
|
||||
description: Define filename for include script in custom directory after installation
|
||||
values: ["none"]
|
||||
default: ["none"]
|
||||
|
||||
[ProductProperty]
|
||||
type: unicode
|
||||
name: custom-post-uninstall
|
||||
multivalue: False
|
||||
editable: True
|
||||
description: Define filename for include script in custom directory after uninstallation
|
||||
values: ["none"]
|
||||
default: ["none"]
|
||||
|
||||
[ProductDependency]
|
||||
action: setup
|
||||
requiredProduct: aio
|
||||
|
Loading…
Reference in New Issue
Block a user