Imported Upstream version 2.20.11.0
This commit is contained in:
parent
abbf8fe002
commit
500025baf6
BIN
amd64/opt/hp/hpssacli/bld/hprmstr
Executable file
BIN
amd64/opt/hp/hpssacli/bld/hprmstr
Executable file
Binary file not shown.
Binary file not shown.
@ -1,83 +1,94 @@
|
|||||||
HP Smart Storage Administrator CLI (HPSSACLI)
|
HP Smart Storage Administrator CLI (HPSSACLI)
|
||||||
Version 2.0-23.0 (linux32)
|
Version 2.20-11.0
|
||||||
7/29/2014
|
5/1/2015
|
||||||
|
|
||||||
Description
|
Description
|
||||||
-----------
|
-----------
|
||||||
The HP Smart Storage Administrator CLI is a command line-based disk
|
The HP Smart Storage Administrator CLI is the command line-based disk
|
||||||
configuration program for Smart Array Controllers.
|
configuration program for Smart Array Controllers.
|
||||||
|
|
||||||
* All other product names mentioned herein may be trademarks of their
|
* All other product names mentioned herein may be trademarks of their
|
||||||
respective companies.
|
respective companies.
|
||||||
|
|
||||||
Support
|
Supported Operating Systems and Platforms
|
||||||
-------
|
-----------------------------------------
|
||||||
|
Linux 32-bit components:
|
||||||
Supported Operating Systems
|
SuSE Linux Enterprise Server 10
|
||||||
|
SuSE Linux Enterprise Server 11
|
||||||
32bit Platforms:
|
|
||||||
Red Hat Enterprise Linux 5
|
Red Hat Enterprise Linux 5
|
||||||
Red Hat Enterprise Linux 6
|
Red Hat Enterprise Linux 6
|
||||||
SuSE Linux Enterprise Server 10, 11
|
Red Hat Enterprise Linux 7
|
||||||
|
|
||||||
64bit Platforms:
|
Linux 64-bit components:
|
||||||
SuSE Linux Enterprise Server 10 (x86_64)
|
SuSE Linux Enterprise Server 10 (x86_64)
|
||||||
SuSE Linux Enterprise Server 11 (x86_64)
|
SuSE Linux Enterprise Server 11 (x86_64)
|
||||||
Red Hat Enterprise Linux 5 (x86_64)
|
Red Hat Enterprise Linux 5 (x86_64)
|
||||||
Red Hat Enterprise Linux 6 (x86_64) with the "Compatibility Package"
|
Red Hat Enterprise Linux 6 (x86_64)
|
||||||
installed to include the 32-bit libraries.
|
Red Hat Enterprise Linux 7 (x86_64)
|
||||||
|
Debian Sarge 64 bit
|
||||||
|
Debian Etch (amd64)
|
||||||
|
|
||||||
* All these platforms need to have the following driver upgrades:
|
NOTE: For Red Hat Enterprise Linux 7.1 the sg driver must be manually
|
||||||
CISS driver version 2.4.50 or later
|
added so that it is loaded at boot time. Without the sg driver being
|
||||||
|
loaded, devices or controllers may not be discovered.
|
||||||
|
Here is a recommended way to do this:
|
||||||
|
|
||||||
These drivers and Fibre Channel HBA drivers are available from
|
sudo echo sg > /etc/modules-load.d/sg.conf
|
||||||
http://www.hp.com.
|
sudo rebo
|
||||||
|
|
||||||
|
* Any platform that requires the CCISS driver should use version 3.6.28 or newer.
|
||||||
|
|
||||||
|
These drivers are available from http://www.hp.com.
|
||||||
|
|
||||||
Supported Controllers
|
Supported Controllers
|
||||||
|
---------------------
|
||||||
|
Dynamic Smart Array B110i SATA RAID
|
||||||
|
Smart Array P212 Controller
|
||||||
|
Smart Array P410 Controller
|
||||||
Smart Array P410i Controller
|
Smart Array P410i Controller
|
||||||
Smart Array P411 Controller
|
Smart Array P411 Controller
|
||||||
Smart Array P212 Controller
|
Smart Array P711m Controller
|
||||||
Smart Array P712m Controller
|
Smart Array P712m Controller
|
||||||
Smart Array B110i SATA RAID
|
|
||||||
Smart Array P812 Controller
|
Smart Array P812 Controller
|
||||||
|
|
||||||
|
Dynamic Smart Array B120i
|
||||||
|
Dynamic Smart Array B320i
|
||||||
Smart Array P220i Controller
|
Smart Array P220i Controller
|
||||||
Smart Array P222 Controller
|
Smart Array P222 Controller
|
||||||
Smart Array P420 Controller
|
Smart Array P420 Controller
|
||||||
Smart Array P420i Controller
|
Smart Array P420i Controller
|
||||||
Smart Array P421 Controller
|
Smart Array P421 Controller
|
||||||
Smart Array P822 Controller
|
|
||||||
Smart Array P721m Controller
|
Smart Array P721m Controller
|
||||||
Dynamic Smart Array B320i RAID
|
Smart Array P822 Controller
|
||||||
Dynamic Smart Array B120i RAID
|
|
||||||
|
|
||||||
|
Smart Array P230i Controller
|
||||||
Smart Array P430 Controller
|
Smart Array P430 Controller
|
||||||
Smart Array P431 Controller
|
Smart Array P431 Controller
|
||||||
Smart Array P731m Controller
|
|
||||||
Smart Array P230i Controller
|
|
||||||
Smart Array P530 Controller
|
Smart Array P530 Controller
|
||||||
Smart Array P531 Controller
|
Smart Array P531 Controller
|
||||||
|
Smart Array P731m Controller
|
||||||
Smart Array P830 Controller
|
Smart Array P830 Controller
|
||||||
Smart Array P830i Controller
|
Smart Array P830i Controller
|
||||||
|
|
||||||
Smart Array P240i Controller
|
|
||||||
Smart Array P440 Controller
|
|
||||||
Smart Array P440i Controller
|
|
||||||
Smart Array P441 Controller
|
|
||||||
Smart Array P840 Controller
|
|
||||||
Smart HBA H240 Controller
|
|
||||||
Smart HBA H240i Controller
|
|
||||||
Smart HBA H241 Controller
|
|
||||||
Smart HBA H244 Controller
|
|
||||||
|
|
||||||
Dynamic Smart Array B110i
|
|
||||||
Dynamic Smart Array B120i
|
|
||||||
Dynamic Smart Array B320i
|
|
||||||
Dynamic Smart Array B140i
|
Dynamic Smart Array B140i
|
||||||
|
Smart HBA H240 Controller
|
||||||
|
Smart HBA H240ar Controller
|
||||||
|
Smart HBA H240tr Controller
|
||||||
|
Smart HBA H241 Controller
|
||||||
|
Smart HBA H244br Controller
|
||||||
|
Smart Array P240tr Controller
|
||||||
|
Smart Array P244br Controller
|
||||||
|
Smart Array P246br Controller
|
||||||
|
Smart Array P440 Controller
|
||||||
|
Smart Array P440ar Controller
|
||||||
|
Smart Array P441 Controller
|
||||||
|
Smart Array P741m Controller
|
||||||
|
Smart Array P840 Controller
|
||||||
|
Smart Array P840ar Controller
|
||||||
|
Smart Array P841 Controller
|
||||||
|
|
||||||
Installing & Running the HP Smart Storage Administrator CLI
|
Installing & Running the HP Smart Storage Administrator
|
||||||
--------------------------------------------------------------
|
--------------------------------------------------------------
|
||||||
|
|
||||||
Installation:
|
Installation:
|
||||||
HPSSACLI is distributed using Red Hat Package Manager (RPM) packages and
|
HPSSACLI is distributed using Red Hat Package Manager (RPM) packages and
|
||||||
.deb packages for Debian.
|
.deb packages for Debian.
|
||||||
@ -94,13 +105,14 @@ Installing & Running the HP Smart Storage Administrator CLI
|
|||||||
When attempting to run HPSSACLI on any HP-supported version of Linux, it is
|
When attempting to run HPSSACLI on any HP-supported version of Linux, it is
|
||||||
highly recommended that you install the latest version of the HP ProLiant
|
highly recommended that you install the latest version of the HP ProLiant
|
||||||
Smart Array Controller driver for your intended Linux operating system.
|
Smart Array Controller driver for your intended Linux operating system.
|
||||||
Drivers may be obtained by clicking on "Support & Drivers" from HP’s
|
Drivers may be obtained by clicking on "Support & Drivers" from HP's
|
||||||
website at: http://www.hp.com
|
website at: http://www.hp.com
|
||||||
|
|
||||||
For Debian 64 bit:
|
For Debian 64 bit:
|
||||||
dpkg -i --force-architecture <file name>. hpssacli requires the libunwind
|
dpkg -i --force-architecture <file name>. hpssacli requires the libunwind
|
||||||
bit package to be installed.
|
bit package to be installed.
|
||||||
|
|
||||||
|
|
||||||
Run the HPSSACLI:
|
Run the HPSSACLI:
|
||||||
|
|
||||||
Make sure that you have gone through the following checklist:
|
Make sure that you have gone through the following checklist:
|
||||||
@ -118,8 +130,6 @@ Installing & Running the HP Smart Storage Administrator CLI
|
|||||||
|
|
||||||
Additional Notes
|
Additional Notes
|
||||||
----------------
|
----------------
|
||||||
|
|
||||||
|
|
||||||
1. After creating or deleting logical drives with HPSSACLI, under some
|
1. After creating or deleting logical drives with HPSSACLI, under some
|
||||||
special circumstances, the device name mapping might change after you
|
special circumstances, the device name mapping might change after you
|
||||||
first reboot the system. Also, Linux might see previously not visible
|
first reboot the system. Also, Linux might see previously not visible
|
||||||
@ -145,7 +155,7 @@ Additional Notes
|
|||||||
8. On RHEL5 systems, for this version of the HPSSACLI version 3.6.18-10 or
|
8. On RHEL5 systems, for this version of the HPSSACLI version 3.6.18-10 or
|
||||||
newer of the HP ProLiant Smart Array Controller Driver for Red Hat
|
newer of the HP ProLiant Smart Array Controller Driver for Red Hat
|
||||||
Enterprise Linux 5 (x86, x86-64) is required. Drivers may be obtained by
|
Enterprise Linux 5 (x86, x86-64) is required. Drivers may be obtained by
|
||||||
clicking on “Support & Drivers” from HP’s website at: http://www.hp.com
|
clicking on "Support & Drivers" from HP's website at: http://www.hp.com
|
||||||
|
|
||||||
|
|
||||||
Notes for HPSSA Scripting
|
Notes for HPSSA Scripting
|
||||||
@ -177,6 +187,6 @@ Notes for HPSSA Scripting
|
|||||||
|
|
||||||
Feedback
|
Feedback
|
||||||
--------
|
--------
|
||||||
|
|
||||||
For support for HPSSACLI or Smart Array controllers, please visit the web at
|
For support for HPSSACLI or Smart Array controllers, please visit the web at
|
||||||
http://support.hp.com.
|
http://support.hp.com.
|
||||||
|
|
Binary file not shown.
Binary file not shown.
@ -13,5 +13,5 @@ ${HPSSACLI_BIN_INSTALLATION_DIR}mklocks.sh hpssacli
|
|||||||
if [ `uname -m` = "ia64" ]; then
|
if [ `uname -m` = "ia64" ]; then
|
||||||
/usr/bin/prctl --unaligned=silent ${HPSSACLI_BIN_INSTALLATION_DIR}hpssacli $*
|
/usr/bin/prctl --unaligned=silent ${HPSSACLI_BIN_INSTALLATION_DIR}hpssacli $*
|
||||||
else
|
else
|
||||||
${HPSSACLI_BIN_INSTALLATION_DIR}hpssacli $*
|
exec ${HPSSACLI_BIN_INSTALLATION_DIR}hpssacli $*
|
||||||
fi
|
fi
|
||||||
|
@ -13,5 +13,5 @@ ${HPSSACLI_BIN_INSTALLATION_DIR}mklocks.sh hpssascripting
|
|||||||
if [ `uname -m` = "ia64" ]; then
|
if [ `uname -m` = "ia64" ]; then
|
||||||
/usr/bin/prctl --unaligned=silent ${HPSSACLI_BIN_INSTALLATION_DIR}hpssascripting $*
|
/usr/bin/prctl --unaligned=silent ${HPSSACLI_BIN_INSTALLATION_DIR}hpssascripting $*
|
||||||
else
|
else
|
||||||
${HPSSACLI_BIN_INSTALLATION_DIR}hpssascripting $*
|
exec ${HPSSACLI_BIN_INSTALLATION_DIR}hpssascripting $*
|
||||||
fi
|
fi
|
||||||
|
BIN
i386/opt/hp/hpssacli/bld/hprmstr
Executable file
BIN
i386/opt/hp/hpssacli/bld/hprmstr
Executable file
Binary file not shown.
Binary file not shown.
@ -1,80 +1,94 @@
|
|||||||
HP Smart Storage Administrator CLI for Linux environments
|
HP Smart Storage Administrator CLI (HPSSACLI)
|
||||||
Version 2.0-23.0 (linuxX64)
|
Version 2.20-11.0
|
||||||
7/29/2014
|
5/1/2015
|
||||||
|
|
||||||
Description
|
Description
|
||||||
-----------
|
-----------
|
||||||
|
The HP Smart Storage Administrator CLI is the command line-based disk
|
||||||
The HP Smart Storage Administrator CLI (HPSSACLI) is a commandline-based
|
configuration program for Smart Array Controllers.
|
||||||
disk configuration program for Smart Array Controllers.
|
|
||||||
|
|
||||||
* All other product names mentioned herein may be trademarks of their
|
* All other product names mentioned herein may be trademarks of their
|
||||||
respective companies.
|
respective companies.
|
||||||
|
|
||||||
Support
|
Supported Operating Systems and Platforms
|
||||||
-------
|
-----------------------------------------
|
||||||
|
Linux 32-bit components:
|
||||||
Supported Operating Systems
|
SuSE Linux Enterprise Server 10
|
||||||
|
SuSE Linux Enterprise Server 11
|
||||||
|
Red Hat Enterprise Linux 5
|
||||||
|
Red Hat Enterprise Linux 6
|
||||||
|
Red Hat Enterprise Linux 7
|
||||||
|
|
||||||
|
Linux 64-bit components:
|
||||||
SuSE Linux Enterprise Server 10 (x86_64)
|
SuSE Linux Enterprise Server 10 (x86_64)
|
||||||
SuSE Linux Enterprise Server 11 (x86_64)
|
SuSE Linux Enterprise Server 11 (x86_64)
|
||||||
Red Hat Enterprise Linux 5 (x86_64)
|
Red Hat Enterprise Linux 5 (x86_64)
|
||||||
Red Hat Enterprise Linux 6 (x86_64) with the "Compatibility Package"
|
Red Hat Enterprise Linux 6 (x86_64)
|
||||||
installed to include the 32-bit libraries.
|
Red Hat Enterprise Linux 7 (x86_64)
|
||||||
Debian Sarge 64 bit
|
Debian Sarge 64 bit
|
||||||
Debian Etch (amd64)
|
Debian Etch (amd64)
|
||||||
|
|
||||||
* All these platforms need to have the following driver upgrades:
|
NOTE: For Red Hat Enterprise Linux 7.1 the sg driver must be manually
|
||||||
CISS driver version 2.4.50 or later
|
added so that it is loaded at boot time. Without the sg driver being
|
||||||
|
loaded, devices or controllers may not be discovered.
|
||||||
|
Here is a recommended way to do this:
|
||||||
|
|
||||||
These drivers and Fibre Channel HBA drivers are available from
|
sudo echo sg > /etc/modules-load.d/sg.conf
|
||||||
http://www.hp.com.
|
sudo rebo
|
||||||
|
|
||||||
|
* Any platform that requires the CCISS driver should use version 3.6.28 or newer.
|
||||||
|
|
||||||
|
These drivers are available from http://www.hp.com.
|
||||||
|
|
||||||
Supported Controllers
|
Supported Controllers
|
||||||
|
---------------------
|
||||||
|
Dynamic Smart Array B110i SATA RAID
|
||||||
|
Smart Array P212 Controller
|
||||||
|
Smart Array P410 Controller
|
||||||
Smart Array P410i Controller
|
Smart Array P410i Controller
|
||||||
Smart Array P411 Controller
|
Smart Array P411 Controller
|
||||||
Smart Array P212 Controller
|
Smart Array P711m Controller
|
||||||
Smart Array P712m Controller
|
Smart Array P712m Controller
|
||||||
Smart Array B110i SATA RAID
|
|
||||||
Smart Array P812 Controller
|
Smart Array P812 Controller
|
||||||
|
|
||||||
|
Dynamic Smart Array B120i
|
||||||
|
Dynamic Smart Array B320i
|
||||||
Smart Array P220i Controller
|
Smart Array P220i Controller
|
||||||
Smart Array P222 Controller
|
Smart Array P222 Controller
|
||||||
Smart Array P420 Controller
|
Smart Array P420 Controller
|
||||||
Smart Array P420i Controller
|
Smart Array P420i Controller
|
||||||
Smart Array P421 Controller
|
Smart Array P421 Controller
|
||||||
Smart Array P822 Controller
|
|
||||||
Smart Array P721m Controller
|
Smart Array P721m Controller
|
||||||
Dynamic Smart Array B320i RAID
|
Smart Array P822 Controller
|
||||||
Dynamic Smart Array B120i RAID
|
|
||||||
|
|
||||||
|
Smart Array P230i Controller
|
||||||
Smart Array P430 Controller
|
Smart Array P430 Controller
|
||||||
Smart Array P431 Controller
|
Smart Array P431 Controller
|
||||||
Smart Array P731m Controller
|
|
||||||
Smart Array P230i Controller
|
|
||||||
Smart Array P530 Controller
|
Smart Array P530 Controller
|
||||||
Smart Array P531 Controller
|
Smart Array P531 Controller
|
||||||
|
Smart Array P731m Controller
|
||||||
Smart Array P830 Controller
|
Smart Array P830 Controller
|
||||||
Smart Array P830i Controller
|
Smart Array P830i Controller
|
||||||
|
|
||||||
Smart Array P240i Controller
|
|
||||||
Smart Array P440 Controller
|
|
||||||
Smart Array P440i Controller
|
|
||||||
Smart Array P441 Controller
|
|
||||||
Smart Array P840 Controller
|
|
||||||
Smart HBA H240 Controller
|
|
||||||
Smart HBA H240i Controller
|
|
||||||
Smart HBA H241 Controller
|
|
||||||
Smart HBA H244 Controller
|
|
||||||
|
|
||||||
Dynamic Smart Array B110i
|
|
||||||
Dynamic Smart Array B120i
|
|
||||||
Dynamic Smart Array B320i
|
|
||||||
Dynamic Smart Array B140i
|
Dynamic Smart Array B140i
|
||||||
|
Smart HBA H240 Controller
|
||||||
|
Smart HBA H240ar Controller
|
||||||
|
Smart HBA H240tr Controller
|
||||||
|
Smart HBA H241 Controller
|
||||||
|
Smart HBA H244br Controller
|
||||||
|
Smart Array P240tr Controller
|
||||||
|
Smart Array P244br Controller
|
||||||
|
Smart Array P246br Controller
|
||||||
|
Smart Array P440 Controller
|
||||||
|
Smart Array P440ar Controller
|
||||||
|
Smart Array P441 Controller
|
||||||
|
Smart Array P741m Controller
|
||||||
|
Smart Array P840 Controller
|
||||||
|
Smart Array P840ar Controller
|
||||||
|
Smart Array P841 Controller
|
||||||
|
|
||||||
Installing & Running the HP Smart Storage Administrator CLI
|
Installing & Running the HP Smart Storage Administrator
|
||||||
--------------------------------------------------------------
|
--------------------------------------------------------------
|
||||||
|
|
||||||
Installation:
|
Installation:
|
||||||
HPSSACLI is distributed using Red Hat Package Manager (RPM) packages and
|
HPSSACLI is distributed using Red Hat Package Manager (RPM) packages and
|
||||||
.deb packages for Debian.
|
.deb packages for Debian.
|
||||||
@ -116,8 +130,6 @@ Installing & Running the HP Smart Storage Administrator CLI
|
|||||||
|
|
||||||
Additional Notes
|
Additional Notes
|
||||||
----------------
|
----------------
|
||||||
|
|
||||||
|
|
||||||
1. After creating or deleting logical drives with HPSSACLI, under some
|
1. After creating or deleting logical drives with HPSSACLI, under some
|
||||||
special circumstances, the device name mapping might change after you
|
special circumstances, the device name mapping might change after you
|
||||||
first reboot the system. Also, Linux might see previously not visible
|
first reboot the system. Also, Linux might see previously not visible
|
||||||
@ -143,7 +155,7 @@ Additional Notes
|
|||||||
8. On RHEL5 systems, for this version of the HPSSACLI version 3.6.18-10 or
|
8. On RHEL5 systems, for this version of the HPSSACLI version 3.6.18-10 or
|
||||||
newer of the HP ProLiant Smart Array Controller Driver for Red Hat
|
newer of the HP ProLiant Smart Array Controller Driver for Red Hat
|
||||||
Enterprise Linux 5 (x86, x86-64) is required. Drivers may be obtained by
|
Enterprise Linux 5 (x86, x86-64) is required. Drivers may be obtained by
|
||||||
clicking on “Support & Drivers” from HP’s website at: http://www.hp.com
|
clicking on "Support & Drivers" from HP's website at: http://www.hp.com
|
||||||
|
|
||||||
|
|
||||||
Notes for HPSSA Scripting
|
Notes for HPSSA Scripting
|
||||||
@ -175,6 +187,6 @@ Notes for HPSSA Scripting
|
|||||||
|
|
||||||
Feedback
|
Feedback
|
||||||
--------
|
--------
|
||||||
|
|
||||||
For support for HPSSACLI or Smart Array controllers, please visit the web at
|
For support for HPSSACLI or Smart Array controllers, please visit the web at
|
||||||
http://support.hp.com.
|
http://support.hp.com.
|
||||||
|
|
Binary file not shown.
Binary file not shown.
@ -13,5 +13,5 @@ ${HPSSACLI_BIN_INSTALLATION_DIR}mklocks.sh hpssacli
|
|||||||
if [ `uname -m` = "ia64" ]; then
|
if [ `uname -m` = "ia64" ]; then
|
||||||
/usr/bin/prctl --unaligned=silent ${HPSSACLI_BIN_INSTALLATION_DIR}hpssacli $*
|
/usr/bin/prctl --unaligned=silent ${HPSSACLI_BIN_INSTALLATION_DIR}hpssacli $*
|
||||||
else
|
else
|
||||||
${HPSSACLI_BIN_INSTALLATION_DIR}hpssacli $*
|
exec ${HPSSACLI_BIN_INSTALLATION_DIR}hpssacli $*
|
||||||
fi
|
fi
|
||||||
|
@ -13,5 +13,5 @@ ${HPSSACLI_BIN_INSTALLATION_DIR}mklocks.sh hpssascripting
|
|||||||
if [ `uname -m` = "ia64" ]; then
|
if [ `uname -m` = "ia64" ]; then
|
||||||
/usr/bin/prctl --unaligned=silent ${HPSSACLI_BIN_INSTALLATION_DIR}hpssascripting $*
|
/usr/bin/prctl --unaligned=silent ${HPSSACLI_BIN_INSTALLATION_DIR}hpssascripting $*
|
||||||
else
|
else
|
||||||
${HPSSACLI_BIN_INSTALLATION_DIR}hpssascripting $*
|
exec ${HPSSACLI_BIN_INSTALLATION_DIR}hpssascripting $*
|
||||||
fi
|
fi
|
||||||
|
Loading…
Reference in New Issue
Block a user