Bump
This commit is contained in:
336
debian/upstream_changelog
vendored
Normal file
336
debian/upstream_changelog
vendored
Normal file
@@ -0,0 +1,336 @@
|
||||
Version: 9.10.22.0 (4 Jun 2012)
|
||||
Enhancements
|
||||
- Added support for the following controllers:
|
||||
* HP Dynamic Smart Array B120i
|
||||
* HP Dynamic Smart Array B320i
|
||||
* HP Smart Array P822
|
||||
- Now officially supporting and providing native X64 versions in addition
|
||||
to existing 32 bit versions
|
||||
- Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:
|
||||
* Replace Array:
|
||||
Allows the transfer of contents of an array to an existing empty
|
||||
array or a new array. All logical drives from the source array will
|
||||
be transferred. The original array will be deleted and its data
|
||||
drives will be freed as unassigned drives. The drive types at source
|
||||
and destination arrays can be different. This allows moving data from
|
||||
SATA to SAS, or SAS to SATA. However, the drive types comprising the
|
||||
array must still be of the same type.
|
||||
* Heal Array:
|
||||
Allows the replacement of failed or degraded physical drives in an
|
||||
array with healthy physical drives. The original array and logical
|
||||
drive numbering will be unaffected after the replacement. The
|
||||
replacement physical drives must be of the same interface type (such
|
||||
as SAS, SATA and etc.) as the original drives. The operation will be
|
||||
available only if enough unassigned physical drives of the correct
|
||||
size are available.
|
||||
|
||||
Version: 9.0.24.0 (27 Mar 2012)
|
||||
Enhancements
|
||||
- Added support for the following controllers:
|
||||
* HP Smart Array P222
|
||||
* HP Smart Array P420
|
||||
* HP Smart Array P421
|
||||
* HP Smart Array P220i
|
||||
* HP Smart Array P420i
|
||||
- Added support for the following features/devices:
|
||||
* Smart Array Advanced Pack 2.0 (SAAP 2.0):
|
||||
SAAP 2.0 provides full SAAP 1.0 feature functionality with the
|
||||
following additions:
|
||||
- RAID 1/10 Advanced Data Mirroring (ADM)
|
||||
- Moving and Deleting of Individual Logical Volumes
|
||||
- Move operation now supports SATA to SAS, SAS to SATA
|
||||
- Predictive Spare Activation
|
||||
- > 128 physical drives
|
||||
- SmartSSD Wear Gauge
|
||||
- Updated Cache Ratio settings
|
||||
- Additional Strip Sizes - 512, 1024 on supported controllers and
|
||||
configurations
|
||||
- Device Temperatures - Controllers, Capacitors, Cache Modules, and
|
||||
Hard Drives
|
||||
- Overall Performance improvements
|
||||
- 3 TB physical drives
|
||||
|
||||
Version: 8.75-12.0 (22 Jun 2011)
|
||||
Enhancements
|
||||
- *** New ***
|
||||
Starting with versions 8.75.12.0, an Offline version of ACU is
|
||||
available from http://www.hp.com/ that allows users to boot directly
|
||||
into the configuration and maintenance utilities prior to any Host OS
|
||||
loading or being installed.
|
||||
.
|
||||
This new deliverable of ACU is available for download through normal
|
||||
software methods (such as searching by Server model, OS, or device) or
|
||||
by searching for 'HP ProLiant Offline Array Configuration Utility'
|
||||
- SmartSSD Wear Gauge
|
||||
This feature is accessible through the ssdinfo command in ACUCLI
|
||||
Example code:
|
||||
<target> show ssdinfo [detail|summary]
|
||||
Provides a summary for solid state drives for the specified controller(s)
|
||||
The target can be any valid controller/device
|
||||
controller slot=1 show sddinfo
|
||||
controller all show ssdinfo
|
||||
controller all show ssdinfo detail
|
||||
controller all show ssdinfo summary
|
||||
- Greater than 2.2 TB Hard Drives
|
||||
|
||||
Version: 8.70-8.0 (11 Mar 2011)
|
||||
Enhancements
|
||||
- Improved speed of Diagnostic report generation
|
||||
- Supported serial logs included in the zip file of the Diagnositc
|
||||
reports, when applicable
|
||||
- New options available during creation of logical drive size
|
||||
- Now showing current and max temperatures for physical drives
|
||||
- Support for failed array controllers. The "ctrl all show" command will
|
||||
list any locked up controllers along with valid controllers. For failed
|
||||
controllers, a message will display explaining its state along with a
|
||||
lockup code, if applicable
|
||||
- Support for "-h" and "-help" commandline option
|
||||
- HPACUSCRIPTING updates:
|
||||
* Will not display array accelerator info in capture files for
|
||||
controllers which do not have cache or the cache is not configurable.
|
||||
Attempting to set the array accelerator on these controllers will
|
||||
result in a warning message (not an error)
|
||||
* Support for logical drive command "Size=MAXMBR". This option creates
|
||||
the largest possible volume in an array with the maximum size
|
||||
constrained by the limits of the 32bit MBR
|
||||
* New keyword, SIZEBLOCKS. Input scripts can now specify size as before
|
||||
using SIZE (size in MB) or SIZEBLOCKS (size in 512 byte blocks) but
|
||||
not both
|
||||
* Now displays the disk interface type in the comment section for physical
|
||||
disks.
|
||||
|
||||
Version: 8.61-1.0 (8 Feb 2011)
|
||||
Fixes
|
||||
- In version 8.60-8.0 of HPACUCLI, using the "show or detail commands" on
|
||||
any target that includes physical drives can cause the application to
|
||||
exit if one or more of the included physical drives are in a failed
|
||||
state.
|
||||
This release, 8.61-1.0, corrects this problem and allows the command to
|
||||
complete successfully.
|
||||
|
||||
Version: 8.60-8.0 (10 Sep 2010)
|
||||
Enhancements
|
||||
- Overall Performance improvements
|
||||
* HPACUCLI as well as in HPACUSCRIPTING
|
||||
- Surface Scan Analysis enhancements
|
||||
* Disable
|
||||
* High
|
||||
* Idle
|
||||
|
||||
Version: 8.50-6.0 (28 May 2010)
|
||||
Enhancements
|
||||
- Overall Performance improvements
|
||||
- Physical drives in a SMART state are allowed to be used at user's
|
||||
discretion
|
||||
- Diagnostic Report additions:
|
||||
* Parity group information for RAID 50 and RAID 60 logical drives
|
||||
* Information for SEP devices and Expanders
|
||||
* Updated Storage Enclosure names
|
||||
- Applicable only with the appropriate SAAP License Key installed:
|
||||
* The Move Array operation now allows the user to move an array to
|
||||
physical drives that are smaller than the original physical drives,
|
||||
provided that all the data in the existing logical drives will fit
|
||||
into the new array
|
||||
* The new drive set must have the same number of physical drives as
|
||||
the existing drive set
|
||||
- Added SEP devices and Expanders to "ctrl slot=X show config" and "ctrl
|
||||
slot=X show config detail" commands
|
||||
- Added an "OS Status" for logical drives to indicate if it is "locked"
|
||||
by the OS
|
||||
- Added display of Hardware Revision info for SAS Expander boards
|
||||
* "<target> enclosure all show detail" should be used in order to see
|
||||
the field displayed
|
||||
- Added support for being able to run ACUCLI in non-interactive mode for
|
||||
read-only commands (show) even if ACU is running. For example:
|
||||
# hpacucli ctrl all show
|
||||
# hpacucli ctrl slot=1 pd all show status
|
||||
- Added "exitonerror" feature which allows the application to exit upon
|
||||
encountering any error during execution of a command. This feature is
|
||||
useful for scripts invoking ACUCLI and the feature will allow scripts
|
||||
to know that an error has occurred.
|
||||
* The setting can also be invoked from the console as an application switch
|
||||
Example: "hpacucli -exitonerror < myscript.txt"
|
||||
* set [exitonerror=enable|disable]
|
||||
Allows a script to decide whether an error encountered during execution
|
||||
* show exitonerror
|
||||
Displays the current exitonerror setting
|
||||
- Added enclosure show support
|
||||
* enclosure [ all | port:box | serialnumber=xxxx ] show [ detail |
|
||||
status]
|
||||
Outputs the storage enclosure information The target can be any
|
||||
valid storage enclosure
|
||||
Examples:
|
||||
* controller slot=5 enclosure all show
|
||||
* controller slot=5 enclosure 4E:1 show detail
|
||||
* controller slot=5 enclosure serialnumber=UAB123456 show status
|
||||
- Added support for the 'show' command to display devices in a logical or
|
||||
physical format similar to the support in ACU (GUI)
|
||||
* set [view=logical|physical]
|
||||
- Allows the user to select whether certain show commands display the
|
||||
output using a logical or physical view
|
||||
- Logical view displays devices using their association with arrays
|
||||
- Physical view displays the devices such as physical drives
|
||||
according to their relationship with their storage enclosures
|
||||
- The default value is logical view
|
||||
* show view
|
||||
- Displays the current view setting.
|
||||
* Examples:
|
||||
set view=physical
|
||||
show view
|
||||
- Added the capability to run multiple commands in command line mode
|
||||
(non-interactive)
|
||||
* The semicolon (";") is used as a delimiter between commands
|
||||
* For example:
|
||||
On LINUX, the semicolon must be escaped or in quotes
|
||||
hpacucli "ctrl slot=1 show; ctrl slot=1 modify
|
||||
drivewritecache=enable; ctrl slot=1 show"
|
||||
- HPACUSCRIPTING Additions:
|
||||
* Now shows an expanded usage message when invalid command line
|
||||
arguments are provided
|
||||
* Added feature to allow RAID=RAID1 for >2 disk mirrors. This
|
||||
allows backwards compatibility with "old" cpqacuxe scripting. Capture
|
||||
will still output correct RAID level
|
||||
* Added AUTO as a valid option for QUEUEDEPTH
|
||||
* Overall Performance improvements
|
||||
* Added Controller=FIRST support. Controllers are now sorted in capture
|
||||
files in slot ascending order
|
||||
* Added additional controller information to errors and warnings to
|
||||
better identify where problems occur in an input file
|
||||
|
||||
Version: 8.40-4.0 (25 Feb 2010)
|
||||
Enhancements
|
||||
- Support for Smart Array P812
|
||||
|
||||
Version: 8.35-7.0 (28 Sep 2009)
|
||||
Enhancements
|
||||
- Changes for HPACUCLI 8.35.X.X:
|
||||
* Now supports command line history and tab completion
|
||||
|
||||
Version: 8.30-5.0 (14 Sep 2009)
|
||||
Enhancements
|
||||
- Changes for HPACUCLI 8.30.X.X:
|
||||
* Enclosure View
|
||||
|
||||
Version: 8.28-13.0 (6 May 2009)
|
||||
Enhancements
|
||||
- Changes for HPACUCLI 8.28.X.X:
|
||||
* Command Line Diagnostics (ADUCLI) is now integrated with HPACUCLI
|
||||
* Scripting for captures and inputs is now intergrated with HPACUCLI
|
||||
This support was previously delivered with ACU
|
||||
The scripting command has changed from cpqacuxe to hpacuscripting
|
||||
|
||||
Version: 8.25.5 (19 Feb 2009)
|
||||
Enhancements
|
||||
- Added Support for the following Controllers:
|
||||
* Smart Array P212
|
||||
* Smart Array P212 ZMR
|
||||
* Smart Array P410
|
||||
* Smart Array P410 ZMR
|
||||
* Smart Array P410i
|
||||
* Smart Array P410i ZMR
|
||||
* Smart Array P411
|
||||
* Smart Array P411 ZMR
|
||||
* Smart Array B110i SATA RAID
|
||||
- Additionally, added support for Advanced Pack
|
||||
|
||||
Version: 8.20.18 (23 Jan 2009)
|
||||
Enhancements
|
||||
- Added Support for the following Controllers:
|
||||
* Smart Array P212
|
||||
* Smart Array P212 ZMR
|
||||
* Smart Array P410
|
||||
* Smart Array P410 ZMR
|
||||
* Smart Array P411
|
||||
* Smart Array P411 ZMR
|
||||
- Additionally, added support for Smart Array Advanced Pack
|
||||
|
||||
Version: 8.10.2 (6 Jun 2008)
|
||||
Fixes
|
||||
- Fixed an issue related to an incorrect Background Parity Initialization
|
||||
status being displayed for RAID 5 and RAID 6 Logical Drives
|
||||
|
||||
Version: 8.0.14 (26 Feb 2008)
|
||||
Enhancements
|
||||
- Added Dual Domain Support for the HP Smart Array P800 Controller
|
||||
- Added 512K Stripe Size for RAID 5 (only on the following controllers
|
||||
with minimum FW 5.00):
|
||||
* Smart Array E500
|
||||
* Smart Array P400/400i
|
||||
* Smart Array P800
|
||||
|
||||
Version: 7.85.18 (24 Jul 2007)
|
||||
Enhancements
|
||||
- Enabled drive write cache for all SAS controllers
|
||||
|
||||
Version: 7.80.6 (27 Apr 2007)
|
||||
Enhancements
|
||||
- Support SATA NCQ status.
|
||||
|
||||
Version: 7.73.1 (26 Mar 2007)
|
||||
Fixes
|
||||
- The ACU CLI utility was modified to display a message informing
|
||||
customers that a firmware update is required if firmware version 2.04
|
||||
is detected on a Smart Array P400, P400i, or P800 controller.
|
||||
Enhancements
|
||||
- Added support for the Smart Array E500 controller.
|
||||
|
||||
Version: 7.70.12 (14 Dec 2006)
|
||||
Enhancements
|
||||
- Changed default RAID5 stripe size to 64K for MSA1000/1500
|
||||
- Added new stripe-sizes (128KB and 256KB) for the P400, P600 and P800
|
||||
controllers to allow migration of volumes from MSA20 to SAS
|
||||
controllers.
|
||||
|
||||
Version: 7.60.18 (25 Sep 2006)
|
||||
Enhancements
|
||||
- CLI now has two new show command parameters -> show [config] [detail].
|
||||
See help for usage.
|
||||
|
||||
Version: 7.50.18 (13 Apr 2006)
|
||||
Enhancements
|
||||
- Added support for the following:
|
||||
* Smart Array P400 Controller
|
||||
* Smart Array P400i Controller
|
||||
* Smart Array E200 Controller
|
||||
* Smart Array E200i Controller
|
||||
- Added support for over 2 TB on controllers that support it.
|
||||
- Array accelerator options are disabled on controllers with zero memory.
|
||||
- When using create, add drives, add spares, and remove spares, the user
|
||||
can now specify drive ranges. Instead of "1:1,1:2,1:3,1:4" the user can
|
||||
type "1:1-1:4".
|
||||
- CLI now supports targeting a controller via the chassis serial number.
|
||||
See help for additional usage information.
|
||||
|
||||
Version: 7.40.7 (9 Sep 2005)
|
||||
Enhancements
|
||||
- Updated so RAID ADG is now referred to as RAID 6 (ADG).
|
||||
|
||||
Version: 7.31.1 (24 Jun 2005)
|
||||
Fixes
|
||||
- Fixes a problem where specifying an array using the “drives” parameter
|
||||
on the create logical drive operation could incorrectly result in
|
||||
deletion of that array if the create operation fails.
|
||||
|
||||
Version: 7.30.9 (4 May 2005)
|
||||
Enhancements
|
||||
- Added support for the following:
|
||||
* Smart Array P600 controller.
|
||||
- Active-Active on redundant controllers that support it.
|
||||
|
||||
Version: 7.21.17 (28 Feb 2005)
|
||||
Enhancements
|
||||
- Added support for Red Hat Enterprise Linux 4.
|
||||
|
||||
Version: 7.20.16 (14 Feb 2005)
|
||||
Fixes
|
||||
- Resolved issue where data in cache was found during reboot.
|
||||
Enhancements
|
||||
- Added support for the standbycontroller=disable command.
|
||||
|
||||
Version: 7.17.1 (11 Dec 2004)
|
||||
Fixes
|
||||
- Corrected ACU CLI caches status messages to better correspond with ACU.
|
||||
|
||||
Version: 7.15.19 (2 Sep 2004)
|
||||
Enhancements
|
||||
- Initial release.
|
||||
Reference in New Issue
Block a user