LSI Megaraid Control and Monitoring Tools by Jefferson Ogata
|
|
------------------------------------------------------------
|
|
|
|
|
|
Disclaimer
|
|
----------
|
|
|
|
WARNING: Use this software at your own risk. The author accepts no
|
|
responsibility for the consequences of your use of this software.
|
|
|
|
WARNING: Use this software at your own risk. The author accepts no
|
|
responsibility for the consequences of your use of this software.
|
|
|
|
WARNING: Use this software at your own risk. The author accepts no
|
|
responsibility for the consequences of your use of this software.
|
|
|
|
These programs directly query megaraid adapters via the ioctl(2) driver
|
|
interface and do a number of undocumented things. I and my colleagues use this
|
|
software regularly and have had no problems, but your mileage may vary. If
|
|
something goes terribly wrong and your RAID configs all get blown away, the
|
|
author accepts no responsibility for the consequences.
|
|
|
|
Please read this document carefully as it contains a warning or two. If you
|
|
have built the programs but are having any issues running them, please see the
|
|
Building, Device Nodes, and Limitations notes further down in this document.
|
|
|
|
|
|
Introduction
|
|
------------
|
|
|
|
I've spent a fair amount of time working out the low-level interface to
|
|
megaraid adapters. This stems from the fact that I use a lot of these beasts
|
|
and have had failures at one time or another. The adapters are fast and
|
|
extremely useful, but they aren't bulletproof. For example, disks showing a
|
|
certain number of media errors are not failed immediately by the adapters; the
|
|
adapters seem to want to pass some threshold of failure before they decide that
|
|
a disk really needs to be dropped from a RAID, and by that time it's possible
|
|
there could be consistency problems. I wrote these tools so I could more
|
|
effectively monitor media errors (dellmgr makes this very tedious) and also
|
|
take advantage of the device self-test functions provided with drives.
|
|
Self-tests are in my opinion a suitable way to detect imminent drive failures
|
|
without tying up the adapter and SCSI bandwidth doing patrol reads. It is also
|
|
very useful to be able to conduct a self-test on a spare disk before using it
|
|
for a rebuild.
|
|
|
|
Another issue I've had with megaraids is keeping current documentation on RAID
|
|
configuration. You may choose a completely logical RAID layout when first
|
|
configuration a system, but that doesn't mean you'll remember it if you have to
|
|
reconstruct it in an emergency--did I leave out a disk for a hot spare? Which
|
|
one? Furthermore, as disks fail and hot spares are rotated in place, the
|
|
configuration changes over time. If you don't update your documentation every
|
|
time a disk fails, you lose track of it. While LSI's MegaCli program provides
|
|
methods for dumping the configuration (although verbosely) and saving and
|
|
restoring it from files, Dell's dellmgr doesn't give you any sensible way to
|
|
track down what spans comprise a logical disk. I wrote these programs in part
|
|
to solve this problem.
|
|
|
|
|
|
Programs
|
|
--------
|
|
|
|
This distribution contains three programs and a script:
|
|
|
|
|
|
*megactl*
|
|
|
|
megactl queries PERC2, PERC3, and PERC4 adapters and reports adapter
|
|
configuration, physical and logical drive condition, drive log sense pages, and
|
|
various other useful information. This allows you to document the actual
|
|
configuration of the adapter, since, for one thing, Dell's dellmgr does not
|
|
tell you which specific logical drive a given disk belongs to.
|
|
|
|
megactl has several features to query SCSI drive log pages, where each drive
|
|
controller saves accumulated error counts, drive temperature, self-test
|
|
results, et al. To get a list of supported log pages for a given drive, use
|
|
"megactl -vv -l 0 <target>" where target is the name of the drive, e.g. a0c1t2
|
|
for SCSI target 2 on channel 1 of adapter 0. In addition "-s" is shorthand for
|
|
"-l 0x10", "-t" is shorthand for "-l 0x0d", and "-e" is shorthand for "-l 0x02
|
|
-l 0x03 -l 0x05". megactl knows how to parse several useful log pages, but
|
|
there are others where you'll have to interpret the results yourself. Feel free
|
|
to write more parsing code.
|
|
|
|
megactl output is governed by a verbosity flag. At lower verbosity levels, the
|
|
program tends to minimize log page output unless it represents an actual
|
|
problem. So to see the full self-test log, you need to add "-vv". I usually run
|
|
the program with a single "-v".
|
|
|
|
Self-test and most status operations allow you to designate either an entire
|
|
adapter (a0), a specific channel (a0c1), or a specific drive (a0c1t2). When
|
|
performing drive self-test operations (q.v.), be sure to specify the actual
|
|
drive you wish to test, or you will end up starting a test on every drive on
|
|
the system. You may designate as many objects as you please, e.g.
|
|
"a0c0t{1,2,3,4,5,8} a0c1 a1".
|
|
|
|
megactl provides a health-check function, which inspects health check operation
|
|
allows only entire adapters to be designated. If no target is designated, the
|
|
program operates on all possible objects.
|
|
|
|
megactl with the -H option performs a health check of all (or specified)
|
|
adapters. By default, the health check checks the state of the adapter battery,
|
|
the state of all logical drives, and for each physical drive, the media error
|
|
count logged by the adapter, the read, write,and verify error log pages, and
|
|
the temperature log page. You can tune the log pages the health check will
|
|
inspect by specifying them with "-e", "-s", "-t", or "-l"; note that if you do
|
|
this, there is no default and you must specify every log page you wish to
|
|
inspect ("-et" for the default behaviour). If a problem is found, the program
|
|
prints the adapter and relevant drive info. If everything is okay, the program
|
|
is completely silent. So "megactl -vH" can be a useful cron job.
|
|
|
|
When using the health check you may specify which adapters you want to check,
|
|
but you may not designate specific channels or drives.
|
|
|
|
megactl also allows you to instruct the drive to perform a long ("-T long") or
|
|
short ("-T short") background self-test procedure, which does not take the
|
|
drive offline. I have performed self-tests on drives that are part of an
|
|
operational RAID many times with no problems. I recommend that you self-test
|
|
only one drive in a given span at a time; if the self-test causes the drive to
|
|
log errors, the adapter may fail the drive, and you don't want that to happen
|
|
to two drives in a span simultaneously or you may lose data.
|
|
|
|
You can get full usage info for megactl by executing it with the -? flag.
|
|
|
|
I use megactl on a number of PERC models, especially PERC3/QCs and PERC4/DCs.
|
|
In the past, megactl was known to work well with PERC2/DC adapters but I no
|
|
longer operate any systems with these adapters, so this may have broken. Please
|
|
let me know if you have success or problems.
|
|
|
|
megactl generally tries not to do anything harmful, so it's pretty safe.
|
|
Primarily it queries disks; the only instructions it issues in its current form
|
|
are to execute self-test operations.
|
|
|
|
|
|
*megasasctl*
|
|
|
|
The second program, megasasctl, is just like megactl, but intended for PERC5
|
|
adapters. The only syntactic difference is that instead of naming targets with
|
|
channels and ids, they are named with enclosures and slots, e.g. a0, a1e0,
|
|
a2e1s9.
|
|
|
|
The SAS support is brand new, and I'm sure I've got some things wrong. I
|
|
haven't been able to fully test SAS support yet because I don't have any bad
|
|
SAS disks.
|
|
|
|
|
|
*megatrace*
|
|
|
|
megatrace is a debugging program which can be used to trace PERC-related
|
|
ioctl() system calls that another program makes. You won't need that unless
|
|
you're trying to add features to megactl, or are exceptionally curious. This
|
|
program uses ptrace(2) and can inspect and modify data structures to help you
|
|
suss out what's going on in dellmgr and MegaCli.
|
|
|
|
|
|
*megarpt*
|
|
|
|
megarpt is a script I run in a cron job each night. It performs a health check
|
|
on all adapters, and emails any problems, along with the adapter configuration,
|
|
to root. It is handy to have the adapter configuration logged in case you need
|
|
to reconstruct adapter state in a catastrophic failure. There are various
|
|
scenarios involving hot spares and multiple drive failures where the adapter
|
|
configuration may not be quite what you thought it was. To use megarpt, copy
|
|
megarpt and megactl into /root/ and add a cron entry for /root/megarpt. Or
|
|
tweak as you see fit; there isn't much to it.
|
|
|
|
megarpt needs to be tweaked for megasasctl applications; it currently works
|
|
only with pre-SAS models.
|
|
|
|
|
|
*megasasrpt*
|
|
|
|
megasasrpt is just like megarpt, but for PERC5 adapters.
|
|
|
|
|
|
Building
|
|
--------
|
|
|
|
This software has been built successfully on RHEL 3, 4, and 5, and Debian Etch,
|
|
using the default gcc compiler, and Red Hat Linux 7.3 or RHEL 2.1 should work
|
|
as well. Simply run make in the src directory.
|
|
|
|
|
|
Device Nodes
|
|
------------
|
|
|
|
megactl and megasasctl require the existence of an appropriate device node in
|
|
order to communicate with adapters. For megactl, this device node should be
|
|
/dev/megadev0, and is created automatically by Dell's dellmgr program. You may
|
|
create it yourself by finding the major device number for megadev in
|
|
/proc/devices and creating a character device with that major number and minor
|
|
number 0. See the megarpt shell script if this is not clear. For megasasctl,
|
|
the device node is /dev/megaraid_sas_ioctl_node, and is created automatically
|
|
by LSI's MegaCli program. It should have the major number of megaraid_sas_ioctl
|
|
from /proc/devices and minor number 0. See the megasasrpt shell script for an
|
|
example of how to create this.
|
|
|
|
|
|
Limitations
|
|
-----------
|
|
|
|
Currently these programs only operate if built as 32-bit targets. On 64-bit
|
|
architectures, you therefore will need 32-bit compatibility libraries. This
|
|
should not require any special action on Red Hat, but on Debian you may need to
|
|
install a few things.
|
|
|
|
|