3DM2™ Online Help

Table of Contents Previous Next Index


Troubleshooting > Error and Notification Messages

0025 Cache flush failed; some data lost
Event Type
Error
Cause
The 3ware RAID controller was not able to commit data to the drive(s) during a caching operation.This is due to a serious drive failure, possibly from a power outage.
Background Information
The 3ware RAID controller uses caching layer firmware to improve performance. For write commands this means that the controller acknowledges it has completed a write operation before the data is committed to disk. If the 3ware RAID controller cannot commit the data to the drive after it has acknowledged to the host, this message is posted.
Action
To troubleshoot the reasons for the failure, collect the logs for your system and contact 3ware technical support at http://www.lsi.com/channel/ContactUs. For information on collecting logs, search the LSI KnowledgeBase for keyword 12278 at http://kb.lsi.com

Table of Contents Previous Next Index
LSI Corporation

Copyright LSI 2004-2010
To contact Support, go to http://www.lsi.com/channel/ContactUs