1
|
In 3DM2, choose Management >> Maintenance.
|
2
|
In the Available Drives list, select the drives you want to include in the unit by marking the checkbox in front of the VPort number for each one.
|
3
|
Click Create Unit.
|
4
|
In the Type field, select the RAID configuration you want.
|
5
|
If stripe size applies to the RAID type you select, select a Stripe Size. (Stripe size does not apply to RAID 1.)
|
6
|
Optional: In the Name box, enter a name for the unit (up to 21 characters, including dashes and underscores).
|
7
|
If you have 12 drives attached to the controller and selected RAID 50 as the configuration in step 3, select whether you want 3, 4, or 6 Drives Per Subunit, as shown here.
|
8
|
Make changes to the unit policies, as desired. You can enable or disable the Write Cache, Auto-Verify, and Overwrite ECC. You can also set the StorSave policy, the Rapid RAID Recovery policy, and the Read Cache policy
|
9
|
Click OK.
|
10
|
Partition, format, and mount the unit. The required steps will vary depending on the operating system. For details, see Partitioning, Formatting, and Mounting Units.
|
Note: For RAID 5 and RAID 6 units with five or more disks, and RAID 50 units with subunits of five drives or more, initialization (synchronization) of the unit begins immediately.
|
LSI Corporation |
Copyright LSI 2004-2010
To contact Support, go to http://www.lsi.com/channel/ContactUs