Configuring Units > Creating a Hot Spare

Creating a Hot Spare
You can designate an available drive as a hot spare. If a redundant unit degrades and a hot spare the size of the degraded disk (or larger) is available, the hot spare will automatically replace the failed drive in the unit without user intervention.
 
Note: When a hot spare replaces a failed drive, an event notification is generated and appears in the list of alarms in 3DM2. You can also have 3DM2 send you an email about this. See Managing E-mail Event Notification.
It is a good idea to create a hot spare after you create a redundant unit.
In order to replace a failed drive, a hot spare must have the same or larger storage capacity than the drive it is replacing, and must be of the same type (SAS or SATA).
The Auto-Rebuild policy allows automatic rebuilding to occur with available drives that are not designated as spares. For more information, see Setting the Auto-Rebuild Policy.
 
Note: 3ware’s 9750 RAID controllers use drive coercion so that drives from differing manufacturers and with slightly different capacities are more likely to be able to be used as spares for each other. Drive coercion slightly decreases the usable capacity of a drive that is used in redundant units.
The capacity used for each drive is rounded down to the nearest GB for drives under 45 GB (45,000,000,000 bytes), and rounded down to the nearest 5 GBytes for drives over 45 GB. For example, a 44.3 GB drive will be rounded down to 44 GBytes, and a 123 GB drive will be rounded down to 120 GBytes.
If you have 120 GB drives from different manufacturers, chances are that the capacity varies slightly. For example, one drive might be 122 GB, and the other 123 GB, even though both are sold and marketed as “120 GB drives.” 3ware drive coercion uses the same capacity for both of these drives so that one could replace the other.
If you need to add a drive to be used as the hot spare, follow the instructions under Adding a Drive.
To specify a hot spare
1
In 3DM2, choose Management >> Maintenance.
2
3
Click Set Spares.
You will see the status change to OK-SPARE.