003F Flash file system error detected
Event Type
Warning
Cause
A corrupted flash file system was found on the 3ware RAID controller during boot-up.
The 3ware RAID controller stores configuration parameters as files in its flash memory. These files can be corrupted when a flash operation is interrupted by events such as a power failure. The controller will attempt to restore the flash files from a backup copy.
Action
Update to the latest firmware, as earlier firmware resets corrupted files to default settings.
We recommend using 3DM2, 3BM, or CLI to check your settings, in case they were not able to be restored.