3DM2™ Online Help

Table of Contents Previous Next Index


Troubleshooting > Error and Notification Messages

002D Source drive error occurred
Event Type
Error
Cause
An error on the source drive was detected during a rebuild operation. The rebuild has stopped as a result.
Action
The controller will report an error, even if the area of the source drive that had the error did not contain data. Scheduling regular verifies will lessen the chance of getting this error.
You can force the rebuild to continue by setting the Overwrite ECC Error policy through 3DM2, 3BM, or CLI, and then rebuilding the unit again. This will cause uncorrectable blocks to be rewritten, but the data may be incorrect. It is recommended that you execute a file system check when the rebuild completes.
Under Windows, right-click on your drive icon and choose Properties >> Tools >> Check Now.
For Mac OS X, you can use the First Aid tab in the Disk Utility—select the disk on the left and then click Verify Disk. If verification encounters problems, you can then use the Repair Disk option on the same screen.
Under Linux and FreeBSD use the fsck command.
For OpenSolaris and VMware you should follow your operating system’s guide to perform a file system check.
See Also
Starting a Verify Manually
Enabling or Disabling Auto-Verify for a Unit
Setting Overwrite ECC (Continue on Source Error When Rebuilding)

Table of Contents Previous Next Index
LSI Corporation

Copyright LSI 2004-2010
To contact Support, go to http://www.lsi.com/channel/ContactUs