3DM2™ Online Help

Table of Contents Previous Next Index


Troubleshooting > Error and Notification Messages

001E Unit inoperable
Event Type
Error
Cause
The 3ware RAID controller is unable to detect sufficient drives for the unit to be operable. Some drives have failed or are missing.
Examples of inoperable units are as follows:
*
*
*
*
Note: The controller only generates this message if the unit is missing drives for more than 20 seconds. This allows a hot swap of a drive to be completed without generating this error.
Action
The unit is no longer available for use. Return all missing drives to the unit. If the drives are physically present, check all data and power connections.
CAUTION: Do not delete the inoperable unit and recreate it as this will overwrite the data and make data recovery very difficult.
You may wish to contact technical support at
http://www.lsi.com/channel/ContactUs.
See Also
About Inoperable Units

Table of Contents Previous Next Index
LSI Corporation

Copyright LSI 2004-2010
To contact Support, go to http://www.lsi.com/channel/ContactUs