3DM2â„¢ Online Help

Table of Contents Previous Next Index


Troubleshooting > Error and Notification Messages

000E Initialize failed
Event Type
Error
Cause
The 3ware RAID controller was unable to complete the initialization. This error can be caused by unrecoverable drive errors.
If this unit was a redundant unit, and the initialization failed because of a problem on a particular disk drive, then the unit will be degraded.
Action
If the unit was degraded, then rebuild the unit. This may necessitate replacing the drive.
Check physical cable and power connections. You can also run the drive manufacturer’s diagnostic and repair utilities on the drive.
See Also
For links to drive manufacturer diagnostic utilities and troubleshooting advice, search the LSI KnowledgeBase for keyword 10894 at
http://kb.lsi.com
Basic Troubleshooting: Check This First

Table of Contents Previous Next Index
LSI Corporation

Copyright LSI 2004-2010
To contact Support, go to http://www.lsi.com/channel/ContactUs