added property machineobjectou for directly joining into an organisation unit; check exitcode <> 0;
advice/description
This commit is contained in:
parent
f787fe5899
commit
5fdf4be5cc
@ -10,6 +10,7 @@ DefVar $domainname$
|
||||
DefVar $joinadmin$
|
||||
DefVar $joinadminpw$
|
||||
DefVar $localadminpw$
|
||||
DefVar $orgunit$
|
||||
DefVar $joinstr$
|
||||
DefVar $MsiId$
|
||||
DefVar $UninstallProgram$
|
||||
@ -26,7 +27,12 @@ Set $LogDir$ = "%SystemDrive%\tmp"
|
||||
Set $domainname$ = GetProductProperty ("domainname","values")
|
||||
Set $joinadmin$ = GetProductProperty ("joinadmin","values")
|
||||
Set $joinadminpw$ = GetProductProperty ("joinadminpw","values")
|
||||
Set $orgunit$ = GetProductProperty ("MachineObjectOU","values")
|
||||
if not ($orgunit$ = "")
|
||||
Set $joinstr$ = "JOIN %PCName% /Domain:" + $domainname$ + " /UserD:" + $joinadmin$ + " /PasswordD:" + $joinadminpw$ + " /OU:" + $orgunit$
|
||||
else
|
||||
Set $joinstr$ = "JOIN %PCName% /Domain:" + $domainname$ + " /UserD:" + $joinadmin$ + " /PasswordD:" + $joinadminpw$
|
||||
endif
|
||||
Set $localadminpw$ = GetProductProperty ("localadminpw","values")
|
||||
|
||||
; The token BUILDER_VARIABLES will be replaced by opsi-builder.sh
|
||||
@ -98,3 +104,15 @@ copy "%ScriptPath%\netdom.exe" %System%
|
||||
net user Administrator $localadminpw$
|
||||
netdom.exe $joinstr$
|
||||
|
||||
[Sub_check_exitcode]
|
||||
comment "Test for installation success via exit code"
|
||||
set $ExitCode$ = getLastExitCode
|
||||
; informations to exit codes see
|
||||
; http://msdn.microsoft.com/en-us/library/aa372835(VS.85).aspx
|
||||
; http://msdn.microsoft.com/en-us/library/aa368542.aspx
|
||||
if ($ExitCode$ = "0")
|
||||
comment "Looks good: setup program gives exitcode zero"
|
||||
else
|
||||
comment "Setup program gives a exitcode unequal zero: " + $ExitCode$
|
||||
isFatalError
|
||||
endif
|
||||
|
11
OPSI/control
11
OPSI/control
@ -7,7 +7,7 @@ incremental: False
|
||||
type: localboot
|
||||
id: windows.domainjoin
|
||||
name: windows.domainjoin
|
||||
description: Package for domainjoin and setting local adminpassword
|
||||
description: Package for joining domain (organisation unit optional) and setting local adminpassword
|
||||
advice: ADVICE
|
||||
version: VERSION
|
||||
priority: PRIORITY
|
||||
@ -39,6 +39,15 @@ description: Domain PC joins
|
||||
values: [""]
|
||||
default: ["DomainName"]
|
||||
|
||||
[ProductProperty]
|
||||
type: unicode
|
||||
name: MachineObjectOU
|
||||
multivalue: False
|
||||
editable: True
|
||||
description: OU moving the new PC to. If empty, the default OU will be used.
|
||||
values: [""]
|
||||
default: [""]
|
||||
|
||||
[ProductProperty]
|
||||
type: unicode
|
||||
name: joinadmin
|
||||
|
@ -6,7 +6,7 @@ PN="windows.domainjoin"
|
||||
VERSION="1"
|
||||
RELEASE="1"
|
||||
PRIORITY="0"
|
||||
ADVICE="Mandatory items: domainname / joinadmin / joinadminpw / localadminpw"
|
||||
ADVICE="Mandatory items: domainname / joinadmin / joinadminpw / localadminpw | Optional items: machineobjectou (RFC 1779)"
|
||||
|
||||
# TYPE - defines, if the install files are public or restricted.
|
||||
# Valid value: restricted | public
|
||||
|