Intial commit

This commit is contained in:
Mario Fetka 2013-08-13 01:54:40 +02:00
commit 5781b13637
14 changed files with 470 additions and 0 deletions

97
CLIENT_DATA/delsub32.ins Normal file
View File

@ -0,0 +1,97 @@
; Copyright (c) uib gmbh (www.uib.de)
; This sourcecode is owned by uib gmbh
; and published under the Terms of the General Public License.
; credits: http://www.opsi.org/en/credits/
Set $UninstallProgram$ = $InstallDir$ + "\" + $UninstallProg$
Set $IniFile$ = $InstallDir$ + "\opsi-" + $ProductId$ + ".ini"
if FileExists($IniFile$)
Set $OLD_VERSION$ = GetValueFromInifile($IniFile$,"COMMON","VERSION","")
Set $OLD_CREATOR_TAG$ = GetValueFromInifile($IniFile$,"COMMON","CREATOR_TAG","")
Set $OLD_RELEASE$ = GetValueFromInifile($IniFile$,"COMMON","RELEASE","")
endif
Message "Uninstalling " + $ProductId$ + " " + $OLD_VERSION$ + "-" + $OLD_CREATOR_TAG$ + $OLD_RELEASE$ + " ..."
if FileExists($IniFile$)
Set $UninstallProg$ = GetValueFromInifile($IniFile$,"X86","UninstallProg","XXXXXXXX.exe")
Set $UninstallProgramOld$ = $InstallDir$ + "\" + $UninstallProg$
if FileExists($UninstallProgramOld$)
comment "Uninstall program found, starting uninstall"
Winbatch_uninstall_old /WaitforProcessending "Au_.exe" /Timeoutseconds 100
sub_check_exitcode
endif
endif
if FileExists($UninstallProgram$)
comment "Uninstall program found, starting uninstall"
Winbatch_uninstall /WaitforProcessending "Au_.exe" /Timeoutseconds 100
sub_check_exitcode
endif
comment "Delete files"
Files_uninstall /32Bit
comment "Cleanup registry"
Registry_uninstall /32Bit
comment "Delete program shortcuts"
LinkFolder_uninstall
[Winbatch_uninstall_old]
"$UninstallProgramOld$" /S
[Winbatch_uninstall]
"$UninstallProgram$" /S
[Files_uninstall]
; Example for recursively deleting the installation directory:
;
del -sf "$InstallDir$\"
[Registry_uninstall]
; Example of deleting a registry key:
;
; deletekey [HKEY_LOCAL_MACHINE\Software\$ProductId$]
[LinkFolder_uninstall]
; Example of deleting a folder from AllUsers startmenu:
;
; set_basefolder common_programs
; delete_subfolder $ProductId$
;
; Example of deleting a shortcut from AllUsers desktop:
;
; set_basefolder common_desktopdirectory
; set_subfolder ""
; delete_element $ProductId$
[Sub_check_exitcode]
comment "Test for installation success via exit code"
set $ExitCode$ = getLastExitCode
; informations to exit codes see
; http://msdn.microsoft.com/en-us/library/aa372835(VS.85).aspx
; http://msdn.microsoft.com/en-us/library/aa368542.aspx
if ($ExitCode$ = "0")
comment "Looks good: setup program gives exitcode zero"
else
comment "Setup program gives a exitcode unequal zero: " + $ExitCode$
if ($ExitCode$ = "1605")
comment "ERROR_UNKNOWN_PRODUCT 1605 This action is only valid for products that are currently installed."
comment "Uninstall of a not installed product failed - no problem"
else
if ($ExitCode$ = "1641")
comment "looks good: setup program gives exitcode 1641"
comment "ERROR_SUCCESS_REBOOT_INITIATED 1641 The installer has initiated a restart. This message is indicative of a success."
else
if ($ExitCode$ = "3010")
comment "looks good: setup program gives exitcode 3010"
comment "ERROR_SUCCESS_REBOOT_REQUIRED 3010 A restart is required to complete the install. This message is indicative of a success."
else
logError "Fatal: Setup program gives an unknown exitcode unequal zero: " + $ExitCode$
isFatalError
endif
endif
endif
endif

24
CLIENT_DATA/login.ins Normal file
View File

@ -0,0 +1,24 @@
; Copyright (c) uib gmbh (www.uib.de)
; This sourcecode is owned by uib gmbh
; and published under the Terms of the General Public License.
; credits: http://www.opsi.org/en/credits/
[Actions]
Message "Profile Patch for VLC ...."
comment "Did we run this script before ? - and set version stamp in profile"
if getValue("installationstate", getProductMap) = "installed"
comment "Product is installed"
if not (scriptWasExecutedBefore)
comment "loginscript was not run yet "
Files_profile_copy
Registry_currentuser_set
endif
endif
[Files_profile_copy]
copy "%Scriptpath%\profiles\*.*" "%CurrentAppdataDir%\ACME"
[Registry_currentuser_set]
openkey [HKCU\Software\ACME]
set "show_greeting_window" = "no"

View File

@ -0,0 +1,5 @@
[X86]
[COMMON]
PN=name
VERSION=version

159
CLIENT_DATA/setup32.ins Normal file
View File

@ -0,0 +1,159 @@
; Copyright (c) uib gmbh (www.uib.de)
; This sourcecode is owned by uib
; and published under the Terms of the General Public License.
; credits: http://www.opsi.org/en/credits/
[Actions]
requiredWinstVersion >= "4.11.2.6"
DefVar $UninstallProgram$
DefVar $UninstallProgramOld$
DefVar $IniFile$
DefVar $IniCfgFile$
DefVar $LogDir$
DefVar $ProductId$
DefVar $MinimumSpace$
DefVar $InstallDir$
DefVar $ExitCode$
DefVar $OLD_VERSION$
DefVar $OLD_CREATOR_TAG$
DefVar $OLD_RELEASE$
Set $LogDir$ = "%SystemDrive%\tmp"
; The token BUILDER_VARIABLES will be replaced by opsi-builder.sh
; and adds the following variables:
; from builder-product.cfg : all variables definded by attribute WINST[index]
; from builder-product.cfg : VENDOR PN VERSION RELEASE PRIORITY ADVICE TYPE
; from opsi-builder.cfg : CREATOR_TAG CREATOR_NAME CREATOR_EMAIL
; auto generated winst-variables
; $IconFile$: path to product picture
;
@@BUILDER_VARIABLES@@
; ----------------------------------------------------------------
; - Please edit the following values -
; ----------------------------------------------------------------
;$ProductId$ should be the name of the product in opsi
; therefore please: only lower letters, no umlauts,
; no white space use '-' as a seperator
Set $MinimumSpace$ = "20 MB"
; the path were we find the product after the installation
Set $InstallDir$ = "%ProgramFiles32Dir%\TeamViewer\Version8"
; ----------------------------------------------------------------
Set $IniCfgFile$ = "%ScriptPath%\opsi-" + $ProductId$ + ".ini"
if not(HasMinimumSpace ("%SystemDrive%", $MinimumSpace$))
LogError "Not enough space on %SystemDrive%, " + $MinimumSpace$ + " on drive %SystemDrive% needed for " + $ProductId$
isFatalError "No Space"
; Stop process and set installation status to failed
else
comment "Show product picture"
ShowBitmap "%ScriptPath%\" + $ProductId$ + ".png" $NAME$
if FileExists("%ScriptPath%\delsub32.ins")
comment "Start uninstall sub section"
Sub "%ScriptPath%\delsub32.ins"
endif
Message "Installing " + $ProductId$ + " "+ $VERSION$ + "-" + $CREATOR_TAG$ + $RELEASE$ + " ..."
comment "Start setup program"
ChangeDirectory "%SCRIPTPATH%"
Winbatch_install
Sub_check_exitcode
comment "Copy files"
Files_install /32Bit
comment "Patch Registry"
Registry_install /32Bit
comment "Create shortcuts"
LinkFolder_install
endif
[Winbatch_install]
"$InstallExe$" /S
[Files_install]
; copy the ini file to the InstallDir
copy "$IniCfgFile$" "$InstallDir$"
; Example of recursively copying some files into the installation directory:
;
; copy -s "%ScriptPath%\files\*.*" "$InstallDir$"
[Registry_install]
; Example of setting some values of an registry key:
;
; openkey [HKEY_LOCAL_MACHINE\Software\$ProductId$]
; set "name1" = "some string value"
; set "name2" = REG_DWORD:0001
; set "name3" = REG_BINARY:00 af 99 cd
[LinkFolder_install]
; Example of deleting a folder from AllUsers startmenu:
;
; set_basefolder common_programs
; delete_subfolder $ProductId$
;
; Example of creating an shortcut to the installed exe in AllUsers startmenu:
;
; set_basefolder common_programs
; set_subfolder $ProductId$
;
; set_link
; name: $ProductId$
; target: <path to the program>
; parameters:
; working_dir: $InstallDir$
; icon_file:
; icon_index:
; end_link
;
; Example of creating an shortcut to the installed exe on AllUsers desktop:
;
; set_basefolder common_desktopdirectory
; set_subfolder ""
;
; set_link
; name: $ProductId$
; target: <path to the program>
; parameters: <some_param>
; working_dir: $InstallDir$
; icon_file: <path to icon file>
; icon_index: 2
; end_link
[Sub_check_exitcode]
comment "Test for installation success via exit code"
set $ExitCode$ = getLastExitCode
; informations to exit codes see
; http://msdn.microsoft.com/en-us/library/aa372835(VS.85).aspx
; http://msdn.microsoft.com/en-us/library/aa368542.aspx
if ($ExitCode$ = "0")
comment "Looks good: setup program gives exitcode zero"
else
comment "Setup program gives a exitcode unequal zero: " + $ExitCode$
if ($ExitCode$ = "1605")
comment "ERROR_UNKNOWN_PRODUCT 1605 This action is only valid for products that are currently installed."
comment "Uninstall of a not installed product failed - no problem"
else
if ($ExitCode$ = "1641")
comment "looks good: setup program gives exitcode 1641"
comment "ERROR_SUCCESS_REBOOT_INITIATED 1641 The installer has initiated a restart. This message is indicative of a success."
else
if ($ExitCode$ = "3010")
comment "looks good: setup program gives exitcode 3010"
comment "ERROR_SUCCESS_REBOOT_REQUIRED 3010 A restart is required to complete the install. This message is indicative of a success."
else
logError "Fatal: Setup program gives an unknown exitcode unequal zero: " + $ExitCode$
isFatalError
endif
endif
endif
endif

View File

@ -0,0 +1,50 @@
; Copyright (c) uib gmbh (www.uib.de)
; This sourcecode is owned by uib gmbh
; and published under the Terms of the General Public License.
; credits: http://www.opsi.org/en/credits/
[Actions]
requiredWinstVersion >= "4.11.2.6"
DefVar $UninstallProgram$
DefVar $UninstallProgramOld$
DefVar $IniFile$
DefVar $IniCfgFile$
DefVar $LogDir$
DefVar $ExitCode$
DefVar $ProductId$
DefVar $InstallDir$
DefVar $OLD_VERSION$
DefVar $OLD_CREATOR_TAG$
DefVar $OLD_RELEASE$
Set $LogDir$ = "%SystemDrive%\tmp"
; The token BUILDER_VARIABLES will be replaced by opsi-builder.sh
; and adds the following variables:
; from builder-product.cfg : all variables definded by attribute WINST[index]
; from builder-product.cfg : VENDOR PN VERSION RELEASE PRIORITY ADVICE TYPE
; from opsi-builder.cfg : CREATOR_TAG CREATOR_NAME CREATOR_EMAIL
; auto generated winst-variables
; $IconFile$: path to product picture
;
@@BUILDER_VARIABLES@@
; ----------------------------------------------------------------
; - Please edit the following values -
; ----------------------------------------------------------------
Set $InstallDir$ = "%ProgramFiles32Dir%\TeamViewer\Version8"
; ----------------------------------------------------------------
Set $IniCfgFile$ = "%ScriptPath%\opsi-" + $ProductId$ + ".ini"
comment "Show product picture"
ShowBitmap "%ScriptPath%\" + $ProductId$ + ".png" $NAME$
Message "Uninstalling " + $ProductId$ + " ..."
if FileExists("%ScriptPath%\delsub32.ins")
comment "Start uninstall sub section"
Sub "%ScriptPath%\delsub32.ins"
endif

2
OPSI/changelog.txt Normal file
View File

@ -0,0 +1,2 @@
Don't add cahngelog entries here!
It get autogenerated by the opsi-builder.sh

30
OPSI/control Normal file
View File

@ -0,0 +1,30 @@
[Package]
version: 2
depends:
incremental: False
[Product]
type: localboot
id: opsi-template
name: opsi template product
description: A template for opsi products
advice:
version: 4.0.2
priority: 0
licenseRequired: False
productClasses:
setupScript: setup32.ins
uninstallScript: uninstall32.ins
updateScript:
alwaysScript:
onceScript:
customScript:
userLoginScript:
[ProductDependency]
action: setup
requiredProduct: sereby.aio
requiredStatus: installed
requirementType: before

9
OPSI/postinst Normal file
View File

@ -0,0 +1,9 @@
#! /bin/sh
#
# postinst script for softprod
# This script executes after unpacking files from that archive and registering the product at the server.
#
# The following environment variables can be used to obtain information about the current installation:
# PRODUCT_ID: id of the current product
# CLIENT_DATA_DIR: directory which contains the installed client data
#

9
OPSI/preinst Normal file
View File

@ -0,0 +1,9 @@
#! /bin/sh
#
# preinst script for softprod
# This script executes before that package will be unpacked from its archive file.
#
# The following environment variables can be used to obtain information about the current installation:
# PRODUCT_ID: id of the current product
# CLIENT_DATA_DIR: directory where client data will be installed
#

View File

@ -0,0 +1 @@
3cad5ff407a5d8b6c23933503bbc4ede921d0b99 /home/mario/.opsi-dist-cache/teamviewer.teamviewer8-8.0.20202/X86/TeamViewer_Setup_de-8.0.20202.exe

View File

@ -0,0 +1 @@
248ca2368561aa1a6040d1fd1f20d94a8b687563 /home/mario/.opsi-dist-cache/teamviewer.teamviewer8-8.0.20202//TeamViewer_logo.png

28
Testing.txt Normal file
View File

@ -0,0 +1,28 @@
*** Qualitiymanagement/Testing procedure
- Product:
- Name: productname
- Version: xxx
- Release: yyyy
- Environment
- OS: Native windows XP-32Bit installation
- Preinstalled packages: None (also no aio)
- Files used while testing:
File1: http://domain.de/file.ext
- Testing process:
OPSI-action:
- Installation (without dependencies like AIO/Firefox): ??
Result:
- File extensions related to program: ??
- Start menu entry: ??
- Starting/using program: viewer works, File1 is shown correctly: ??
OPSI-action:
- Uninstall
Result:
- File extensions related to program: unrelated: ??
- Start menu entry: none: ??

30
builder-product.cfg Normal file
View File

@ -0,0 +1,30 @@
############################
# Setup product information
############################
VENDOR="teamviewer.com"
PN="teamviewer.teamviewer8"
NAME="TeamViewer 8"
DESCRIPTION="TeamViewer - die All-In-One Software fuer Fernwartung und Online Meeting"
VERSION="8.0.20202"
RELEASE="3"
PRIORITY="0"
ADVICE=""
# TYPE - defines, if the install files are public or restricted.
# Valid value: restricted | public
TYPE="public"
DL_FILE[0]="TeamViewer_logo.png"
DL_SOURCE[0]="http://www.meindesire.de/wp-content/uploads/2010/11/TeamViewer_logo.png"
DL_FILE[1]="TeamViewer_Setup_de-${VERSION}.exe"
DL_SOURCE[1]="http://download.teamviewer.com/download/TeamViewer_Setup_de.exe"
DL_ARCH[1]="X86"
DL_WINST_NAME[1]=InstallExe
# File array index for the image showing while installing the program
ICON_DL_INDEX=0
OPSI_INI_SECTION[0]="X86"
OPSI_INI_OPTION[0]="UninstallProg"
OPSI_INI_VALUE[0]="uninstall.exe"

25
builder-targets-cb.sh Normal file
View File

@ -0,0 +1,25 @@
##############################################################################
# This optional file "builder-targets-cb.sh" will be called by builder.sh
#
# The targets will be called from thde opsi-builder using the following
# order: config, prepare, retrieve, create, package, publish, commit, cleanup
# You can overwrite the target functions in builder-targets-cb.sh
#
# You can define callback functions. The functions are called from
# opsi-builder within processing a target
# cb_package_makeproductfile
#
# You can use every variable defined in any configuration file or by
# the defined builder script itself. Also, calling the predefined
# targets builder_<targetname> is possible.
#
# Abstract:
# target order: config, prepare, retrieve, create, package, publish, commit, cleanup
# callbacks: <none>
#
##############################################################################
function cleanup() {
echo "Cleanup"
builder_cleanup
}