2011-06-29 21:24:13 +02:00
|
|
|
; Copyright (c) uib gmbh (www.uib.de)
|
|
|
|
; This sourcecode is owned by uib
|
|
|
|
; and published under the Terms of the General Public License.
|
2013-03-18 12:38:48 +01:00
|
|
|
; credits: http://www.opsi.org/en/credits/
|
2011-06-29 21:24:13 +02:00
|
|
|
|
|
|
|
[Actions]
|
2013-03-18 12:38:48 +01:00
|
|
|
requiredWinstVersion >= "4.11.2.6"
|
2011-06-29 21:24:13 +02:00
|
|
|
|
2013-03-18 12:38:48 +01:00
|
|
|
DefVar $MsiIdOld$
|
|
|
|
DefVar $IniFile$
|
|
|
|
DefVar $IniCfgFile$
|
2011-06-29 21:24:13 +02:00
|
|
|
DefVar $LogDir$
|
|
|
|
DefVar $ProductId$
|
|
|
|
DefVar $MinimumSpace$
|
|
|
|
DefVar $InstallDir$
|
|
|
|
DefVar $ExitCode$
|
2013-03-18 12:38:48 +01:00
|
|
|
DefVar $OLD_VERSION$
|
|
|
|
DefVar $OLD_CREATOR_TAG$
|
|
|
|
DefVar $OLD_RELEASE$
|
2011-06-29 21:24:13 +02:00
|
|
|
|
|
|
|
Set $LogDir$ = "%SystemDrive%\tmp"
|
|
|
|
|
2013-03-18 12:38:48 +01:00
|
|
|
; The token BUILDER_VARIABLES will be replaced by opsi-builder.sh
|
|
|
|
; and adds the following variables:
|
|
|
|
; from builder-product.cfg : all variables definded by attribute WINST[index]
|
|
|
|
; from builder-product.cfg : VENDOR PN VERSION RELEASE PRIORITY ADVICE TYPE
|
|
|
|
; from opsi-builder.cfg : CREATOR_TAG CREATOR_NAME CREATOR_EMAIL
|
|
|
|
; auto generated winst-variables
|
|
|
|
; $IconFile$: path to product picture
|
|
|
|
;
|
2012-01-28 22:14:52 +01:00
|
|
|
@@BUILDER_VARIABLES@@
|
|
|
|
|
2011-06-29 21:24:13 +02:00
|
|
|
; ----------------------------------------------------------------
|
|
|
|
; - Please edit the following values -
|
|
|
|
; ----------------------------------------------------------------
|
|
|
|
;$ProductId$ should be the name of the product in opsi
|
|
|
|
; therefore please: only lower letters, no umlauts,
|
|
|
|
; no white space use '-' as a seperator
|
2012-01-19 22:35:31 +01:00
|
|
|
Set $MinimumSpace$ = "30 MB"
|
2011-06-29 21:24:13 +02:00
|
|
|
; the path were we find the product after the installation
|
2012-01-19 22:35:31 +01:00
|
|
|
Set $InstallDir$ = "%ProgramFiles32Dir%\SoftMaker Viewer\PlanMaker"
|
2011-06-29 21:24:13 +02:00
|
|
|
; ----------------------------------------------------------------
|
|
|
|
|
2013-03-18 12:38:48 +01:00
|
|
|
Set $IniCfgFile$ = "%ScriptPath%\opsi-" + $ProductId$ + ".ini"
|
|
|
|
|
2011-06-29 21:24:13 +02:00
|
|
|
if not(HasMinimumSpace ("%SystemDrive%", $MinimumSpace$))
|
|
|
|
LogError "Not enough space on %SystemDrive%, " + $MinimumSpace$ + " on drive %SystemDrive% needed for " + $ProductId$
|
2013-03-18 12:38:48 +01:00
|
|
|
isFatalError "No Space"
|
2011-06-29 21:24:13 +02:00
|
|
|
; Stop process and set installation status to failed
|
|
|
|
else
|
|
|
|
comment "Show product picture"
|
2013-03-18 12:38:48 +01:00
|
|
|
ShowBitmap "%ScriptPath%\" + $ProductId$ + ".png" $NAME$
|
2011-06-29 21:24:13 +02:00
|
|
|
|
|
|
|
if FileExists("%ScriptPath%\delsub32.ins")
|
|
|
|
comment "Start uninstall sub section"
|
|
|
|
Sub "%ScriptPath%\delsub32.ins"
|
|
|
|
endif
|
|
|
|
|
2013-03-18 12:38:48 +01:00
|
|
|
Message "Installing " + $ProductId$ + " "+ $VERSION$ + "-" + $CREATOR_TAG$ + $RELEASE$ + " ..."
|
2011-06-29 21:24:13 +02:00
|
|
|
|
|
|
|
comment "Start setup program"
|
2013-03-18 12:38:48 +01:00
|
|
|
ChangeDirectory "%SCRIPTPATH%"
|
2011-06-29 21:24:13 +02:00
|
|
|
Winbatch_install
|
|
|
|
Sub_check_exitcode
|
|
|
|
|
|
|
|
comment "Copy files"
|
|
|
|
Files_install /32Bit
|
|
|
|
|
|
|
|
comment "Patch Registry"
|
|
|
|
Registry_install /32Bit
|
|
|
|
|
|
|
|
comment "Create shortcuts"
|
|
|
|
LinkFolder_install
|
|
|
|
|
|
|
|
endif
|
|
|
|
|
|
|
|
[Winbatch_install]
|
2013-03-18 12:38:48 +01:00
|
|
|
msiexec /i "$InstallMsi$" /l* "$LogDir$\$ProductId$.install_log.txt" /qb! ALLUSERS=1 REBOOT=ReallySuppress
|
2011-06-29 21:24:13 +02:00
|
|
|
|
|
|
|
[Files_install]
|
2013-03-18 12:38:48 +01:00
|
|
|
; copy the ini file to the InstallDir
|
|
|
|
copy "$IniCfgFile$" "$InstallDir$"
|
|
|
|
copy "$IniCfgFile$" "$InstallDir$\SoftMaker\Settings\pmv10config.ini"
|
|
|
|
|
2011-06-29 21:24:13 +02:00
|
|
|
; Example of recursively copying some files into the installation directory:
|
|
|
|
;
|
2013-03-18 12:38:48 +01:00
|
|
|
; copy -s "%ScriptPath%\files\*.*" "$InstallDir$"
|
2011-06-29 21:24:13 +02:00
|
|
|
|
|
|
|
[Registry_install]
|
|
|
|
; Example of setting some values of an registry key:
|
|
|
|
;
|
|
|
|
; openkey [HKEY_LOCAL_MACHINE\Software\$ProductId$]
|
|
|
|
; set "name1" = "some string value"
|
|
|
|
; set "name2" = REG_DWORD:0001
|
|
|
|
; set "name3" = REG_BINARY:00 af 99 cd
|
|
|
|
|
|
|
|
[LinkFolder_install]
|
|
|
|
; Example of deleting a folder from AllUsers startmenu:
|
|
|
|
;
|
|
|
|
; set_basefolder common_programs
|
|
|
|
; delete_subfolder $ProductId$
|
|
|
|
;
|
|
|
|
; Example of creating an shortcut to the installed exe in AllUsers startmenu:
|
|
|
|
;
|
2012-01-19 22:35:31 +01:00
|
|
|
; set_basefolder common_programs
|
|
|
|
; set_subfolder $ProductId$
|
|
|
|
;
|
|
|
|
; set_link
|
|
|
|
; name: $ProductId$
|
|
|
|
; target: <path to the program>
|
|
|
|
; parameters:
|
|
|
|
; working_dir: $InstallDir$
|
|
|
|
; icon_file:
|
|
|
|
; icon_index:
|
|
|
|
; end_link
|
2011-06-29 21:24:13 +02:00
|
|
|
;
|
|
|
|
; Example of creating an shortcut to the installed exe on AllUsers desktop:
|
|
|
|
;
|
|
|
|
; set_basefolder common_desktopdirectory
|
|
|
|
; set_subfolder ""
|
|
|
|
;
|
|
|
|
; set_link
|
|
|
|
; name: $ProductId$
|
|
|
|
; target: <path to the program>
|
|
|
|
; parameters: <some_param>
|
|
|
|
; working_dir: $InstallDir$
|
|
|
|
; icon_file: <path to icon file>
|
|
|
|
; icon_index: 2
|
|
|
|
; end_link
|
|
|
|
|
|
|
|
[Sub_check_exitcode]
|
|
|
|
comment "Test for installation success via exit code"
|
|
|
|
set $ExitCode$ = getLastExitCode
|
|
|
|
; informations to exit codes see
|
|
|
|
; http://msdn.microsoft.com/en-us/library/aa372835(VS.85).aspx
|
|
|
|
; http://msdn.microsoft.com/en-us/library/aa368542.aspx
|
|
|
|
if ($ExitCode$ = "0")
|
|
|
|
comment "Looks good: setup program gives exitcode zero"
|
|
|
|
else
|
|
|
|
comment "Setup program gives a exitcode unequal zero: " + $ExitCode$
|
|
|
|
if ($ExitCode$ = "1605")
|
|
|
|
comment "ERROR_UNKNOWN_PRODUCT 1605 This action is only valid for products that are currently installed."
|
|
|
|
comment "Uninstall of a not installed product failed - no problem"
|
|
|
|
else
|
|
|
|
if ($ExitCode$ = "1641")
|
|
|
|
comment "looks good: setup program gives exitcode 1641"
|
|
|
|
comment "ERROR_SUCCESS_REBOOT_INITIATED 1641 The installer has initiated a restart. This message is indicative of a success."
|
|
|
|
else
|
|
|
|
if ($ExitCode$ = "3010")
|
|
|
|
comment "looks good: setup program gives exitcode 3010"
|
|
|
|
comment "ERROR_SUCCESS_REBOOT_REQUIRED 3010 A restart is required to complete the install. This message is indicative of a success."
|
|
|
|
else
|
|
|
|
logError "Fatal: Setup program gives an unknown exitcode unequal zero: " + $ExitCode$
|
|
|
|
isFatalError
|
|
|
|
endif
|
|
|
|
endif
|
|
|
|
endif
|
|
|
|
endif
|
|
|
|
|